A study of single bubbles growing on a microscale heater array kept at nominally constant temperature was performed. The heater array consisted of 96 heaters each nominally 0.27 mm × 0.27 mm in size. The heater temperatures were kept constant using electronic feedback loops similar to those used in hot-wire anemometry, and the power required to do this was measured throughout the bubble departure cycle for each heater in the array. Data were obtained at a wall superheat of 22.5 °C during saturated pool boiling of FC-72. Bubbles were observed to nucleate from a single site on the surface at this temperature. Evaluation of various heat transfer models are made.
No takes yet. Share an insight, caveat, or question.
Yaddanapudi et al. (2000) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: