This analysis investigates optical efficiency in solar concentrators, indicating new control metrics.
This study systematically investigates the impact of various deviations on the optical performance of Fixed Reflector Parabolic Concentrators. Based on ray-tracing simulations, a comprehensive analytical method for evaluating deviation effects was developed. This method quantifies the influence of key parameters—including reflector angle and surface profile deviations, tracker angle deviations, receiver position deviations, and concentrator orientation deviations—on the geometric optical efficiency. This methodology was applied to analyse two representative design cases, employing contour maps to illustrate optical efficiency variations under different deviation conditions and defining permissible deviation ranges corresponding to various efficiency thresholds. Building upon this, recommended control metrics for various deviations are proposed, alongside optimization strategies—such as adjusting the receiver position or modifying the tracking model—to enhance the system's tolerance capability. Findings indicate that the recommended deviation control metrics for this concentrator are lower than the existing standards for linear concentrators, and as the aspect ratio of the concentrator decreases, its tolerance capability improves, while the peak efficiency decreases. This study provides theoretical support for the design, application, and optimization of Fixed Reflector Parabolic Concentrators.
No takes yet. Share an insight, caveat, or question.