Case report describes primary malposition of a PICC into the left pericardiophrenic vein, highlighting the necessity of multimodal imaging when standard tip tracking fails.
We report a case of primary malposition of a PICC inserted by guidewire replacement in the emergency room. Intraprocedural tip location by intracavitary electrocardiography was not feasible because the patient had atrial fibrillation; intraprocedural tip location by ultrasound (using the so-called "bubble test") showed that the tip was not in the superior vena cava or in the right atrium. A post-procedural chest X-ray confirmed the malposition but could not precise the location of the tip. A CT scan (scheduled for other purposes) finally visualized the tip in a very unusual location, the left pericardiophrenic vein.