Key result
Percutaneous loop snare retrieval successfully removes a migrated 6 cm PICC fragment from the RV.
Why the study?
The study aims to describe a case of peripherally inserted central catheter fracture and migration to the right ventricle and analyze its risk factors, mechanisms, and the role of diagnostic imaging.
Case Report (n=1)
No
Percutaneous endovascular retrieval using a loop snare system is a safe and effective method for removing migrated PICC fragments from the right ventricle, even in asymptomatic patients.
May prompt vigilance for PICC integrity in oncology patients; leaves open prospective studies on incidence and prevention.
This study describes a case of fracture and migration of a peripherally inserted central catheter (PICC) identified as an electrode fragment during an endovascular procedure. It analyzes risk factors, mechanisms, and the role of diagnostic imaging for rapid fragment identification. A 65-year-old woman with colon carcinoma had a PICC placed for chemotherapy. Routine chest radiography revealed a linear foreign body near the cardiac silhouette. Computed tomography (CT) confirmed a migrated fragment in the right ventricle. Despite no symptoms, urgent intervention was required due to the intracardiac location. The fragment, identified as a catheter fragment from the PICC, was removed percutaneously using a loop snare system without complications, and the patient was discharged in good condition. Literature indicates that PICC fracture and migration are rare but serious, potentially causing arrhythmias, pulmonary embolism, infections, or valvular damage. Causes include defective materials, mechanical compression (e.g., pinch-off syndrome), improper placement/removal, or material wear. Symptoms vary from none to severe. Early diagnosis relies on radiological surveillance, with chest radiography as the initial step, followed by CT and echocardiography for precise localization. The percutaneous endovascular approach is the preferred treatment due to its efficacy and safety. This case underscores the importance of vigilant radiological follow-up, even in asymptomatic patients, to detect anomalies that could jeopardize safety. CT enabled rapid diagnosis and planning, while the endovascular procedure ensured safe fragment removal and quick recovery. The case highlights the need for healthcare professionals to monitor device integrity and functionality, emphasizing early diagnosis through advanced imaging and prompt intervention to ensure favorable outcomes in complex oncological patients.
No takes yet. Share an insight, caveat, or question.
Faggian et al. (2025) conducted a case report in PICC fracture and migration (n=1). Endovascular percutaneous removal using a loop snare system was evaluated on Successful removal of the migrated PICC fragment. An asymptomatic 6 cm migrated PICC fragment in the right ventricle was successfully removed percutaneously using a loop snare system without complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: