This is the authors' abstract. We don't add key points for this paper.
A theoretical model is developed to describe the hydrodynamic behavior of the vapor-liquid interface of a bubble at the heater surface leading to the initiation of critical heat flux (CHF) condition. The momentum flux resulting from evaporation at the bubble base is identified to be an important parameter. A model based on theoretical considerations is developed for upward-facing surfaces with orientations of 0 deg (horizontal) to 90 deg (vertical). It includes the surface-liquid interaction effects through the dynamic receding contact angle. The CHF in pool boiling for water, refrigerants and cryogenic liquids is correctly predicted by the model, and the parametric trends of CHF with dynamic receding contact angle and subcooling are also well represented.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Satish G. Kandlikar (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: