Answers are grounded in this paper and cite their sources.
In order to assess structural safety conditions, many vibration-based damage detection methods have been developed in recent years. Among these methods, transmissibility function analysis can offer advantages in easy and low-cost implementation, as well as independency to the magnitude and waveform of an excitation record. Harnessing these features, a decentralized structural damage detection procedure is proposed in this paper. The proposed procedure only requires measurements in one small area at a time, and thus, is ideal for using limited number of sensors upon a large-scale structure. This study also investigates the nature of transmissibility functions for damage detection in an analytical manner, based on a chain-like spring–mass–damper system with multiple degrees-of-freedom. The analytical derivation is validated through numerical simulation and laboratory experiments using mobile sensors.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2015) studied this question.