Fig. 1. AI-enhanced echocardiographic assessment of AS continuum. The illustration depicts a dual-pathway AI system for evaluating AS. The top row illustrates the DL-based assessment of the AS continuum using limited views, providing a unique DL index for the AS continuum, termed DLi-ASc. The bottom row demonstrates the automated AS assessment, which derives conventional echocardiographic AS parameters. By integrating both pathways, our AI system enables accurate AS diagnosis and prognostication, making it broadly applicable in advanced and resource-limited settings. AS, aortic stenosis; DL, deep-learning; DLi-ASc, DL index for the AS continuum.
Fig. 2. The distribution of DLi-ASc according to AS severity and UMAP visualization. (a) The DLi-ASc, generated by the DL-based AS continuum algorithm, showed a consistent trend of increasing scores with the progression of AS severity observed across both internal and external datasets. (b) The UMAP plot demonstrates a continuous nonlinear gradient transition from the normal state (grey) through AV sclerosis (yellow) to advanced AS stages (red), visually underscoring the DLi-ASc accurately representing the AS continuum. Abbreviations as in Fig. 1: DHDS, distinct hospital dataset; ITDS, internal test dataset; TDDS, temporally distinct dataset; UMAP, uniform manifold approximation and projection.
Fig. 3. Explainability analysis using saliency map. The figure displays representative PLAX and PSAX views alongside their corresponding Grad-CAM saliency maps during DLi-ASc calculation. The saliency maps highlight that the DL model accurately focuses on the AV. As AS severity progresses from normal to severe AS, the model produces increasingly higher DLi-ASc scores, corresponding worsening AS. Abbreviations as in Fig. 1: AV, aortic valve; PLAX parasternal long-axis view; PSAX, parasternal short-axis view.
Fig. 4. Concordance in AS diagnosis between DL-based automated assessment and conventional evaluation. (a) Across all datasets, the auto-measured AS parameters (AV maximal velocity, mean pressure gradient, and valve area) strongly correlated with those obtained from manual measurements. (b) Consequently, AS gradings from both methods exhibited a high concordance rate, ranging from 82.1% to 96.8%. Abbreviations as in Fig. 2, Fig. 3, Fig. 4: AVA, aortic valve area; LVOT, left ventricular outflow tract; MAE, mean absolute error; mPG, mean pressure gradient; r, Spearman Correlation Coefficient; Vmax, maximal velocity.
Fig. 5. Diagnostic performances of DLi-ASc and other AI-derived conventional AS parameters across various stages. The discriminative ability of DLi-ASc and other conventional AS parameters was consistently excellent for diagnosing any AS, significant AS (moderate to severe), and severe AS across all datasets: (a) ITDS, (b) DHDS, and (c) TDDS. Abbreviations as in Fig. 2, Fig. 4: AUC, the area under the curve; DLi-ASc, DL index for the AS continuum.
Fig. 6. Spline curves for composite outcomes associated with DLi-ASc. The risk of composite outcome gradually increased with higher DLi-ASc across all datasets: (a) ITDS, (b) DHDS, and (c) TDDS. The solid lines represent the hazard ratio, and the blue shaded area represents the 95% confidence interval. Abbreviations as in Fig. 2, Fig. 4.
Fig. 7. Prognostic value of DLi-ASc and AS parameters. The DLi-ASc showed independent predictive value for composite outcomes. Similarly, other AI-derived AS parameters were significant predictors for composite outcomes as well as manually-derived AS parameters. Abbreviations as in Fig. 2, Fig. 3, Fig. 4: HR, hazard ratio.
Key points are not available for this paper at this time.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Park et al. (2025) studied this question.