Key result
VirtuoSEW-assisted microinvasive mitral valve repair eliminates severe MR in 100% of patients without perioperative complications.
Why the study?
Totally endoscopic mitral valve repair can be technically challenging, particularly for precise annuloplasty suturing, prompting evaluation of the VirtuoSEW automated annular suturing system.
Does the VirtuoSEW automated annular suturing system safely and effectively facilitate totally endoscopic microInvasive mitral valve repair in patients with severe mitral valve disease?
Does the VirtuoSEW automated annular suturing system safely and effectively facilitate totally endoscopic microInvasive mitral valve repair in patients with severe mitral valve disease?
The VirtuoSEW automated suturing system is safe and feasible for totally endoscopic microInvasive mitral valve repair, achieving 100% elimination of severe mitral regurgitation with no early complications in an initial cohort.
May expand options for totally endoscopic mitral repair; extends evidence for automated suturing but leaves open long-term outcomes.
Background/Objectives: Totally endoscopic mitral valve repair reduces surgical trauma and accelerates recovery but can be technically challenging, particularly for precise annuloplasty suturing. The VirtuoSEW® (LSI Solutions, Victor, NY 14564m, USA) automated annular suturing system was developed to standardize and simplify suture placement. This study was an early evaluation of this technology’s safety, efficacy, and feasibility in totally endoscopic microInvasive mitral valve repair (µMVr). Methods: We conducted a retrospective observational study of 20 patients with severe mitral valve disease of various etiologies. All patients underwent mitral valve repair using the VirtuoSEW® system for automated placement of annuloplasty sutures, combined with leaflet resection or chordal management as appropriate. Postoperative outcomes were assessed at one month using echocardiography and clinical evaluation. Perioperative and postoperative complications and early mortality were systematically recorded. Results: VirtuoSEW®-assisted mitral valve repair was safe and effective, achieving complete elimination of severe mitral regurgitation in all patients (N = 20, 100%). Annuloplasty rings included Physio-ring (N = 12, 60%), Memo 3D (N = 4, 20%), and Memo 4D (N = 4, 20%), combined with leaflet repair techniques: leaflet plication (N = 5, 25%), neochordae implantation (N = 7, 35%), sliding plasty (N = 2, 10%), commissural repair (N = 1, 5%), and hemibutterfly repair (N = 1, 5%). Concomitant procedures included: tricuspid valve repair (N = 1, 5%) and atrial septal defect closure (N = 1, 5%). Mitral annulus diameter decreased from 42.0 ± 5.3 mm to 34.2 ± 2.2 mm (p = 0.001). Mean total surgery, cardiopulmonary bypass, and aortic cross-clamp times were 170.3 ± 21.3, 143.4 ± 21.5, and 80.4 ± 7.9 min, respectively. ICU stay was 1.0 ± 0.2 days, with a hospital stay of 8.0 ± 1.9 days. No perioperative complications—including bleeding (N = 0, 0%), stroke (N = 0, 0%), infections (N = 0, 0%), or 30-day mortality (N = 0, 0%)—occurred. Conclusions: µMVR invasive mitral valve repair using the VirtuoSEW® system is safe, effective, and reproducible, as well as compatible with almost all repair techniques, providing complete restoration of valve competence with no early device-related complications. To our knowledge, this is the first clinical study reporting outcomes with this device, supporting its potential to streamline mitral repair and improve procedural efficiency.
No takes yet. Share an insight, caveat, or question.
Granov et al. (2026) studied this question. VirtuoSEW®-assisted microinvasive mitral valve repair safely eliminated severe mitral regurgitation in 100% of patients (N=20) with zero perioperative complications or 30-day mortality.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: