Key result
Automated annular suturing achieves 100% technical success without device failures during minimally invasive valve replacement.
Why the study?
Annular suturing remains a technically demanding step in minimally invasive cardiac valve surgery, prompting evaluation of the feasibility, safety, and operational integration of an automated annular suturing device.
Does automated annular suturing using the RAM device improve technical success and safety in patients undergoing minimally invasive valve replacement?
Observational (n=43)
No
Does automated annular suturing using the RAM device improve technical success and safety in patients undergoing minimally invasive valve replacement?
Automated annular suturing using the RAM device is technically feasible and safe in minimally invasive mitral and aortic valve replacement, achieving 100% technical success with stable operative times.
Answers are grounded in this paper and cite their sources.
May inform workflow integration in minimally invasive valve programs; leaves open randomized confirmation of outcomes versus manual suturing.
Background: Minimally invasive cardiac valve surgery (MIVS) provides distinct clinical advantages, yet annular suturing remains a technically demanding step. Automated annular suturing devices (RAM®) have been developed to standardize suture placement during valve replacement. This study evaluates the initial clinical feasibility, technical safety, and operational integration of automated suturing during its institutional adoption phase. Methods: We retrospectively evaluated 43 consecutive patients undergoing MIVS supported by the RAM® system (2021–2025), stratified into mitral valve replacements (RAM-MVR, n = 26) and aortic valve replacements (RAM-AVR, n = 17). Technical parameters, procedural safety metrics, and perioperative outcomes were descriptively analyzed and contextualized against our broader institutional MIVS platform using percutaneous femoral cannulation (n = 182). Results: Automated annular suturing achieved a 100% technical feasibility rate (43/43, 95% CI: 91.8–100.0%) with zero mechanical device failures or intraoperative suture-line disruptions (0%, 95% CI: 0.0–8.2%). In the RAM-MVR cohort, median cross-clamp and cardiopulmonary bypass (CPB) times were 73.0 min (IQR 64.0–91.0) and 114.5 min (IQR 94.8–129.5), respectively. In RAM-AVR, median cross-clamp time was 75.0 min (IQR 71.0–83.0). Thirty-day mortality was 4.7% (2/43, 95% CI: 0.6–15.8%), secondary to non-device-related medical complications in high-risk baseline patients. Postoperative echocardiography demonstrated no paravalvular regurgitation (0%, 95% CI: 0.0–8.2%). Conclusions: Initial institutional experience demonstrates that automated annular suturing is technically feasible and safe in minimally invasive mitral and aortic valve replacement. The system enables consistent procedural execution across valve positions. These observational data support automated suturing as a feasible alternative to manual suturing in MIVS workflows.
No takes yet. Share an insight, caveat, or question.
Balan et al. (2026) conducted an observational in Minimally invasive cardiac valve surgery (mitral or aortic valve replacement) (n=43). Automated annular suturing device (RAM) was evaluated on Technical success (successful automated placement of all annular sutures without conversion to manual suturing or device failure) (95% CI 91.8-100.0). The automated annular suturing device achieved a 100% technical feasibility rate with zero mechanical device failures in minimally invasive valve replacement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: