Answers are grounded in this paper and cite their sources.
Achieving operational stability at high current densities remains a challenge in CO2 electrolyzers due to flooding of the gas diffusion layer (GDL) that supports the electrocatalyst. We mitigated electrode flooding at high current densities using a vacuum-assisted infiltration method to embed 200–400 nm-sized polytetrafluoroethylene (PTFE) particles at the interface of the microporous layer (MPL) and carbon cloth in a commercial GDL. In CO2 electrolysis to CO over a silver nanoparticle catalyst on the GDL, the PTFE-embedded GDL not only just exhibited less than 10% of the electrolyte seepage rates observed in untreated GDLs at a current density of 300 mA·cm–2 but also expanded the electrochemical active area across the testing conditions. The PTFE-embedded GDL also maintained a Faradaic efficiency for CO2 electrolysis to CO above 80% for more than 100 h at 100 mA·cm–2, which was a 50-fold improvement in the stable operation time of the electrolyzer.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: