Why the study?
The efficacy of anteriolateral versus anterior-posterior electrode positions in the success of external electrical cardioversion of AF was unclear.
Does anteriolateral electrode position improve the success rate of external cardioversion in patients with atrial fibrillation compared to anterior-posterior position?
Does anteriolateral electrode position improve the success rate of external cardioversion in patients with atrial fibrillation compared to anterior-posterior position?
The anteriolateral electrode position is more effective than the anterior-posterior position for external cardioversion of atrial fibrillation, particularly in patients aged 60 or older, those with left atrial diameter >45 mm, and those receiving fewer than 5 shocks.
Answers are grounded in this paper and cite their sources.
Supports anterolateral positioning for higher AF cardioversion success; extends pooled evidence on electrode placement.
The efficacy of anteriolateral versus anterior-posterior electrode positions in the success of atrial fibrillation's (AF) electrical cardioversion is unclear. Our aim is to perform a meta-analysis to compare the success rate of both electrode positions. PUBMED, WOS, OVID, and SCOPUS were searched. Inclusion criteria were clinical trials that compared anterior-lateral with anterior-posterior electrodes in external cardioversion of AF. After the full-text screening, 11 trials were included in the analysis. The total number of patients included in the study is 1845. The pooled analysis showed a statistically significant association between anterior-lateral electrode and increased cardioversion rate of AF (odds ratio [OR] = 1.40, 95% confidence interval [CI] = 1.02-1.92, p = .04). Subgroup analysis revealed a statistically significant association between the anterior-lateral electrode and increased cardioversion rate of AF in subgroups of less than five shocks, patients with 60 years old or more and patients with left atrial (LA) diameter >45 mm (OR = 1.72, 95% CI = 1.17-2.54, p = .006), (OR = 1.73, 95% CI = 1.18-2.54, p = .005), and (OR = 1.86, 95% CI = 1.04-3.34, p = .04), respectively. Anteriolateral electrode is more effective than anterior-posterior electrode in external cardioversion of AF, particularly in patients who have received less than 5 shocks, are 60 years old or older and have a LA diameter greater than 45 mm.
No takes yet. Share an insight, caveat, or question.
Motawea et al. (2023) studied this question.