Why the study?
Assessing and improving public knowledge of AF could increase detection and stroke prevention, but no validated AF knowledge assessment tool existed for the general population.
Is the Atrial Fibrillation Knowledge Assessment Tool (AFKAT) a valid and reliable instrument for assessing AF knowledge?
Is the Atrial Fibrillation Knowledge Assessment Tool (AFKAT) a valid and reliable instrument for assessing AF knowledge?
The AFKAT is a valid and reliable instrument for assessing atrial fibrillation knowledge in the general population.
AFKAT may identify knowledge gaps across groups; leaves open whether its use improves AF outcomes or warrants routine adoption.
Assessing and improving public knowledge of atrial fibrillation (AF) could increase its detection rate and the subsequent use of stroke prevention therapies. However, there is no validated AF knowledge assessment tool applicable to the general population, including those at risk of AF. Therefore, we aimed to develop and validate such a tool. The tool was developed from a literature review and discussion with subject matter experts. Content validity was ensured by a ten-member panel of experts comprising cardiologists and pharmacists. An online validation survey was conducted and reported based on the Checklist for Reporting Results of Internet E-Surveys (CHERRIES). The survey evaluated the tool performance by construct validity, internal consistency reliability, item discrimination, difficulty index and ease of readability. The survey participants included 14 general medical specialists, 20 fourth-year and 33 second-year undergraduate pharmacy students, and 122 members of the general public. The tool had satisfactory content validity, with a scale content validity index of 0.8. The mean percentage knowledge scores for general medical specialists and fourth-year pharmacy students were higher than second-year pharmacy students, followed by the general public (92.9%, 87.6%, 68.5% and 53.4%, respectively; p-value < 0.001), supporting construct validity. The tool had good internal consistency reliability (Cronbach's alpha = 0.91). The item-total correlation was in the preferred range of 0.23 to 0.71. The Atrial Fibrillation Knowledge Assessment Tool is a valid instrument and can be used to investigate AF knowledge of the general population.
No takes yet. Share an insight, caveat, or question.
Abubakar et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: