Key result
Dynamic multi-session template fusion partially mitigates ECG biometric degradation from temporal drift and unseen identities.
Why the study?
Many prior studies of ECG biometrics report overly optimistic results due to data leakage, such as random splits within the same session.
A new benchmarking framework for ECG biometrics reveals that standard intra-session evaluations artificially inflate performance, highlighting the need for cross-session testing to account for temporal drift.
Demands caution for clinical ECG biometric deployment; challenges intra-session evaluations and extends multi-session template fusion.
Electrocardiogram (ECG) biometrics have emerged as a promising modality for continuous, liveness-aware authentication in wearable systems. However, many prior studies report overly optimistic results due to data leakage (e.g., random splits within the same session). To address this issue, we introduce ECG-biometrics-bench, a modular, reproducible benchmarking framework that standardizes preprocessing, segmentation, and evaluation across seven widely used public ECG datasets spanning clinical, ambulatory, and large-scale cohort settings. The framework supports both closed-set and open-set (i.e., subject-disjoint generalization in this work) evaluation, as well as progressively realistic protocols including cross-session and long-term temporal separation. To facilitate reproducible research in the community, the ECG-biometrics-bench repository will be made publicly accessible on GitHub upon the acceptance of this manuscript. Through a comprehensive multi-dataset analysis, we expose the Random Split Fallacy, demonstrating that intra-session evaluation protocols artificially inflate performance while masking severe degradation caused by temporal drift and unseen identities. Furthermore, by evaluating multiple architectures, including DeepECG, ResNet1D, and CNN-LSTM, we show that these failures are not model-specific but are likely inherent to current supervised feature-learning paradigms. Finally, we demonstrate that performance degradation due to temporal aging can be partially mitigated through a heavy enrollment, lightweight authentication strategy based on dynamic multi-session template fusion. These findings establish a more realistic baseline for ECG biometrics and highlight critical challenges that must be addressed for reliable real-world deployment.
No takes yet. Share an insight, caveat, or question.
Milad Parvan (2026) studied this question. ECG biometric models experience severe performance degradation from temporal drift and unseen identities, which can be partially mitigated through dynamic multi-session template fusion.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: