PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 12, 2026Medicine0 citationsOpen Access

Comparative and diagnostic evaluation of maternal serum prostasin in early-onset preeclampsia

View Full Paper
GBGökhan BollukSOSüleyman Cemil OğlakZYZeynep Kayaoğlu Yildirim

Key Result

Maternal serum prostasin levels were significantly elevated in early-onset preeclampsia versus healthy controls (31.66 vs 22.33 ng/mL; P<.001), with levels >26.44 ng/mL increasing risk ~20-fold.

Key Points

  • The study aims to compare maternal serum prostasin levels in early-onset preeclampsia and healthy pregnant women, establishing its potential as a biomarker.
  • Conducted a prospective case-control study with 43 women diagnosed with early-onset preeclampsia and 45 healthy controls.
  • Measured demographic characteristics, complete blood count, biochemical parameters, and serum prostasin concentrations.
  • Generated a receiver operating characteristic curve to assess prostasin's sensitivity and specificity.
  • Determined optimal cutoff values for clinical application using the Youden index.
  • Maternal serum prostasin levels were significantly higher in early-onset preeclampsia group (31.66 ng/mL) compared to controls (22.33 ng/mL).
  • The area under the curve was 0.820, indicating strong discriminative ability for early-onset preeclampsia.
  • Optimal cutoff for serum prostasin was ≥26.44 ng/mL, with sensitivity of 0.837 and specificity of 0.778.
  • A prostasin value >26.44 ng/mL increases the risk of early-onset preeclampsia by approximately 20-fold.

Study Design

Type

Case-Control (n=88)

Structured PICO

Are maternal serum prostasin levels elevated in early-onset preeclampsia compared to healthy pregnancies, and can they serve as a diagnostic biomarker?

P
Population
88 pregnant women, including 43 diagnosed with early-onset preeclampsia between 20 0/7 to 34 0/7 weeks of gestation and 45 healthy pregnant controls.
I
Intervention
Measurement of maternal serum prostasin levels
C
Comparator
Healthy pregnant controls
O
Outcome
Maternal serum prostasin levels and diagnostic performance (AUC, sensitivity, specificity) for early-onset preeclampsiasurrogate

Maternal serum prostasin levels are significantly elevated in early-onset preeclampsia and demonstrate strong diagnostic performance as a potential biomarker.

Main Result

Effect estimate: AUC 0.820 (95% CI 0.729-0.912)

Absolute Event Rate: 31.66% vs 22.33%

p-value: p=<.001

Abstract

We aimed to compare maternal serum prostasin levels between women with early-onset preeclampsia (PE) and healthy pregnant controls to establish pathophysiological differences. We also sought to evaluate the diagnostic performance of maternal serum prostasin as a potential biomarker for early-onset PE, including determination of optimal cutoff values for clinical application. This was a prospective case–control study including 43 pregnant women who were diagnosed with early-onset PE between 20 0/7 to 34 0/7 weeks of gestation from March to September 2022. Also, 45 healthy pregnant women were included in the control group. Demographic characteristics, complete blood count and biochemical parameters, and serum prostasin concentrations were documented. A receiver operating characteristic curve was generated to demonstrate the sensitivity and specificity of prostasin, and the optimal cutoff value was determined using the Youden index. The median maternal serum prostasin level was found to be significantly higher in the early-onset PE group (31.66 27.12–51.00 ng/mL) compared to the control group (22.33 16.03–25.89 ng/mL) with a P -value 26.44 ng/mL increases the risk of early-onset PE by approximately 20-fold. Maternal serum prostasin levels are significantly elevated in early-onset preeclamptic mothers compared to the healthy controls. These findings suggest that prostasin may play a role in early-onset PE pathophysiology and could serve as a biomarker for its diagnosis.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bolluk et al. (2026) conducted a case-control in early-onset preeclampsia (n=88). Maternal serum prostasin vs. Healthy pregnant controls was evaluated on Maternal serum prostasin level (AUC 0.820, 95% CI 0.729-0.912, p=<.001). Maternal serum prostasin levels were significantly elevated in early-onset preeclampsia versus healthy controls (31.66 vs 22.33 ng/mL; P<.001), with levels >26.44 ng/mL increasing risk ~20-fold.

synapsesocial.com/papers/69db383b4fe01fead37c6728https://doi.org/10.1097/md.0000000000048323
Ask AI
Helpful
Bookmark
Share
View Full Paper