Answers are grounded in this paper and cite their sources.
Semi-invasive monitoring of conjunctival oxygen reveals correlation with arterial oxygen, indicating practical applications and limitations.
Semi-invasive transconjunctival oxygen monitoring uses a miniaturized Clark electrode to measure the oxygen tension of the palpebral conjunctiva (PcjO 2 ). We designed this study to determine the normal value for the conjunctival index (PcjO 2 /PaO 2 ), to evaluate the correlation between PcjO 2 and PaO 2 over a wide PaO 2 range, to evaluate the short-term stability of the conjunctival index with changes in PaO 2 , and to evaluate some of the practical aspects of conjunctival oxygen monitoring. Materials and Methods: The Insight Eyelid Oxygen Monitor was used. We measured PcjO 2 , pH, PaO 2 , and PaCO 2 and calculated the conjunctival index in 16 healthy volunteers under conditions of normoxemia, hypoxemia, and hyperoxemia. In addition, subjects used a questionnaire to report their experience with the eyelid sensor. Results: The mean PcjO 2 (66 ± SD 32 torr, range 14-157 torr) was significantly different from the mean PaO 2 (99 ± 47 torr, range 34-221 torr) (P < 0.001). The mean conjunctival index was 0.68 ± 0.15 (range 0.41-0.98). The correlation coefficient for the overall relationship between PcjO 2 and PaO 2 was 0.91. When the conjunctival index was determined on the same individual at two PaO 2 levels, there was a statistically significant mean difference of 0.16 in the two conjunctival index values (P < 0.002). Our staff learned to use the conjunctival oxygen monitoring system with a minimum of practice. All subjects found the placement of the sensor at least mildly uncomfortable, six subjects stated that they would prefer not to have conjunctival oxygen monitoring used on them if they were critically ill, five subjects found the eyelid sensor more uncomfortable than arterial puncture, one subject experienced severe irritation and pus formation, and two experienced mild itching and irritation. Conclusions: Conjunctival oxygen monitoring is a relatively simple but not entirely innocuous means of monitoring tissue oxygenation. Although the overall correlation between PcjO 2 and PaO 2 is good in hemodynamically normal persons, the inter- and intra-individual variability in the conjunctival index limits its usefulness as an accurate reflection of PaO 2 . When PcjO 2 monitoring is used, we recommend that it be used in conjunction with periodic measurement of PaO 2 to assess overall tissue oxygen delivery.
No takes yet. Share an insight, caveat, or question.
Hess et al. (1986) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: