Key result
Higher baseline peak vortex volume on 4D flow MRI predicts progression to AVR in moderate AS.
Why the study?
Abnormal vortex formation may reflect haemodynamic alterations associated with AS progression and eventual AVR.
Does baseline peak vortex volume measured by 4D flow MRI predict progression to aortic valve replacement in patients with moderate aortic stenosis?
Cohort (n=15)
No
Does baseline peak vortex volume measured by 4D flow MRI predict progression to aortic valve replacement in patients with moderate aortic stenosis?
Abnormal vortex formation assessed by 4D flow MRI may serve as a novel haemodynamic marker to predict disease progression and the need for aortic valve replacement in patients with moderate aortic stenosis.
Answers are grounded in this paper and cite their sources.
May identify moderate AS patients at risk for AVR; hypothesis-generating for 4D flow MRI, needs prospective validation.
BACKGROUND: Predicting progression to aortic valve replacement (AVR) in moderate aortic stenosis (AS) is challenging. This study explored whether haemodynamic parameters from four-dimensional flow MRI (4D flow MRI) are associated with the potential progression to AVR. METHODS: 15 patients with moderate AS underwent baseline 4D flow MRI and echocardiography, with repeat echocardiography within 2 years. Patients were categorised into AVR (n=8) or no-AVR (n=7) groups based on whether they underwent AVR during follow-up. RESULTS: AVR occurred a mean of 396±156 days after baseline. The AVR group had higher follow-up peak velocity (p=0.001), mean pressure gradient (p=0.022) and smaller valve area (p=0.004). Baseline peak vortex volume was greater in the AVR group (p=0.009) and was associated with AVR with an area under the curve of 0.88 (95% CI 0.82 to 1.00). Peak vortex volume moderately correlated with baseline (r=0.69) and follow-up (r=0.63) peak velocity and baseline mean pressure gradient (r=0.59) measured by echocardiography. CONCLUSION: Abnormal vortex formation may reflect haemodynamic alterations associated with AS progression and eventual AVR. These exploratory results should be validated in larger cohorts to define the potential role of 4D flow MRI-based vortex assessments in AS evaluation.
No takes yet. Share an insight, caveat, or question.
Park et al. (2025) conducted a cohort in Moderate aortic stenosis (n=15). Baseline 4D flow MRI-derived peak vortex volume vs. No aortic valve replacement (no-AVR group) was evaluated on Progression to aortic valve replacement (AVR) (AUC 0.88, 95% CI 0.82-1.00, p=0.009). Baseline peak vortex volume measured by 4D flow MRI was significantly greater in patients with moderate aortic stenosis who subsequently required aortic valve replacement compared to those who did not.
Synapse has enriched 10 related papers. Consider them for comparative context: