This is the authors' abstract. We don't add key points for this paper.
Lower anode catalyst loadings and higher current densities are essential to lowering the levelized cost of H 2 production via proton exchange membrane water electrolysis (PEMWE). However, these approaches can induce significant durability challenges. Here, we show that cell degradation can include large reversible voltage losses across a variety of conditions, including low loadings and high currents. Although there is limited published discussion of reversible voltage losses in PEMWE, we demonstrate that they are an important consideration in cell efficiency and durability. Understanding the mechanisms of reversible losses and developing mitigation strategies is therefore a key priority for enabling low-cost PEMWE.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Blair et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: