Current echocardiographic criteria for severe aortic stenosis exhibit high internal inconsistencies, especially in patients with low stroke volumes, suggesting a need for refined diagnostic cut-offs.
Answers are grounded in this paper and cite their sources.
May prompt caution applying current severe AS criteria in low-flow states; leaves open need for gender- and race-specific thresholds in prospective studies.
Our findings demonstrated gender- and race-related differences in AS progression and underscored the need to refine the multiparametric criteria for diagnosis of severe AS to minimize internal inconsistencies, which are high with the current cut-offs and amplified in patients with low stroke volumes.
No takes yet. Share an insight, caveat, or question.
Kebed et al. (2020) studied this question.