PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 14, 2009Anesthesia & Analgesia216 citations

The Ability of Stroke Volume Variations Obtained with Vigileo/FloTrac System to Monitor Fluid Responsiveness in Mechanically Ventilated Patients

View Full Paper
MCMaxime CannessonHMHenri MusardODOlivier Desebbe

Structured PICO

Does stroke volume variation obtained with the Vigileo/FloTrac system accurately predict fluid responsiveness in mechanically ventilated patients undergoing CABG?

P
Population
25 mechanically ventilated patients under general anesthesia referred for coronary artery bypass grafting, monitored with a pulmonary artery catheter.
I
Intervention
Stroke volume variation (SVV) monitoring using the Vigileo/FloTrac system before and after intravascular volume expansion (500 mL hetastarch).
C
Comparator
Respiratory variations in arterial pulse pressure (ΔPP).
O
Outcome
Prediction of fluid responsiveness (defined as >15% increase in cardiac index obtained using thermodilution after volume expansion).surrogate

Stroke volume variation obtained via the Vigileo/FloTrac system provides a reliable, automatic method for continuous monitoring of fluid responsiveness in mechanically ventilated patients.

Abstract

In Brief BACKGROUND: Respiratory variations in arterial pulse pressure (ΔPP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. The aim of our study was to assess the ability of a novel algorithm for automatic estimation of stroke volume variation (SVV) to predict fluid responsiveness in mechanically ventilated patients. METHODS: We studied 25 patients referred for coronary artery bypass grafting. SVV was continuously displayed by the Vigileo/FloTrac system. All patients were under general anesthesia, mechanical ventilation and were also monitored with a pulmonary artery catheter. SVV and ΔPP were recorded simultaneously before and after an intravascular volume expansion (VE) (500 mL hetastarch). Responders to VE were defined as patients whose cardiac index obtained using thermodilution increased by more than 15% after VE. RESULTS: Agreement between ΔPP and SVV over the 50 pairs of collected data was −1.3% ± 2.8% (mean bias ± sd). Seventeen patients were responders to VE. A threshold ΔPP value of 10% allowed discrimination of responders to VE with a sensitivity of 88% and a specificity of 87%. A threshold SVV value of 10% allowed discrimination of responders to VE with a sensitivity of 82% and a specificity of 88%. CONCLUSION: SVV predicts fluid responsiveness with an acceptable sensitivity and specificity and is also a potential surrogate for continuous monitoring of ΔPP. IMPLICATIONS: Stroke volume variations obtained with the Vigileo-FloTrac system allow continuous and automatic monitoring of fluid responsiveness in mechanically ventilated patients. This new device may have clinical impact for fluid optimization in the operating room.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cannesson et al. (2009) studied this question.

synapsesocial.com/papers/69dd198aa6f240e91f1336e6https://doi.org/10.1213/ane.0b013e318192a36b