This is the authors' abstract. We don't add key points for this paper.
In this paper, fault diagnosis and fault-tolerant control strategies have been studied comprehensively for dual three-phase permanent-magnet synchronous motor (PMSM) drives to improve the reliability. Based on direct torque control (DTC) with space vector modulation, a series of diagnostic and tolerant control methods have been proposed for five types of faults, namely, speed-sensor fault, dc-link voltage-sensor fault, current-sensor fault, open-phase fault, and open-switch fault. First, diagnosis and tolerant schemes are proposed for speed-sensor fault by estimating the rotor angle speed with the rotating speed of stator flux. Second, diagnosis and tolerant schemes are proposed for dc-link voltage-sensor fault by combining the current model based stator flux observer with the voltage model based stator flux observer. Third, a three-step method is designed to diagnose three types of faults related to current signals, namely, current-sensor fault, open-phase fault, and open-switch fault simultaneously. A vector space decomposition based current estimation method is proposed to achieve fault-tolerant control for the current-sensor fault, and the voltage compensation based fault-tolerant control is presented for both open-phase and open-switch faults. The experiments have been taken on a laboratory prototype to verify the effectiveness of the proposed fault diagnosis and fault-tolerant schemes.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: