Why the study?
Guidelines suggest a 12-item score and a d-dimer cutoff of 500 ng/mL for suspected acute aortic syndromes, but a simplified score and more specific cutoff could be advantageous.
Does the simplified AORTAs score integrated with age-adjusted d-dimer improve diagnostic accuracy for acute aortic syndromes compared to the standard aortic dissection detection score?
Does the simplified AORTAs score integrated with age-adjusted d-dimer improve diagnostic accuracy for acute aortic syndromes compared to the standard aortic dissection detection score?
The simplified AORTAs score integrated with age-adjusted d-dimer provides improved sensitivity and classification for diagnosing acute aortic syndromes compared to the standard ADD score.
Answers are grounded in this paper and cite their sources.
May support sensitive rule-out of acute aortic syndromes; hypothesis-generating and should not yet change practice.
Background When acute aortic syndromes (AASs) are suspected, pretest clinical probability assessment and d-dimer (DD) testing are diagnostic options allowing standardized care. Guidelines suggest use of a 12-item/3-category score (aortic dissection detection) and a DD cutoff of 500 ng/mL. However, a simplified assessment tool and a more specific DD cutoff could be advantageous. Methods and Results In a prospective derivation cohort (n=1848), 6 items identified by logistic regression (thoracic aortic aneurysm, severe pain, sudden pain, pulse deficit, neurologic deficit, hypotension), composed a simplified score (AORTAs) assigning 2 points to hypotension and 1 to the other items. AORTAs≤1 and ≥2 defined low and high clinical probability, respectively. Age-adjusted DD was calculated as years/age × 10 ng/mL (minimum 500). The AORTAs score and AORTAs≤1/age-adjusted DD rule were validated in 2 patient cohorts: a high-prevalence retrospective cohort (n=1035; 22% AASs) and a low-prevalence prospective cohort (n=447; 11% AASs) subjected to 30-day follow-up. The AUC of the AORTAs score was 0.729 versus 0.697 of the aortic dissection detection score (P=0.005). AORTAs score assessment reclassified 16.6% to 25.1% of patients, with significant net reclassification improvement of 10.3% to 32.7% for AASs and -8.6 to -17% for alternative diagnoses. In both cohorts, AORTAs≥2 had superior sensitivity and slightly lower specificity than aortic dissection detection ≥2. In the prospective validation cohort, AORTAs≤1/age-adjusted DD had a sensitivity of 100%, a specificity of 48.6%, and an efficiency of 43.3%. Conclusions AORTAs is a simplified score with increased sensitivity, improved AAS classification, and minor trade-off in specificity, amenable to integration with age-adjusted DD for diagnostic rule-out.
No takes yet. Share an insight, caveat, or question.
Morello et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: