High-amplitude AMF (up to 1,300 Oe) was well tolerated provided the duty was adjusted to dissipate heat. Results presented suggest that further tissue temperature regulation can be achieved with suitable variations of pulse width for a given amplitude and duty combination. These results suggest that it is possible to apply high-amplitude AMF (> 500 Oe) with pulsing for a time sufficient to treat cancer tissue in which magnetic nanoparticles have been embedded.
No takes yet. Share an insight, caveat, or question.
Ivkov et al. (2005) studied this question.