In this in vitro cadaver study, an increase in flexion angle, an increase in valgus torque, and resection of > or =6 mm led to an increase in strain in the anterior bundle of the medial collateral ligament. The non-uniform change in strain related to 3 mm of resection suggests that resections of the posteromedial aspect of the olecranon of >3 mm may jeopardize the function of the anterior bundle.