None of the evaluated suture materials provided clearly superior properties over the others during both cyclic loading and load-to-failure testing. Based on the results of this study, FiberWire™ may be the preferred suture material for transtibial pull-out repair of posterior meniscus root tears because of comparably low displacement during cyclic loading and high values for maximum load and stiffness. In the clinical setting, FiberWire™ may improve healing rates and avoid progressive extrusion of the meniscus after transtibial pull-out repair of posterior meniscus root tears.
No takes yet. Share an insight, caveat, or question.
Feucht et al. (2013) studied this question.