December 6, 2017Journal of Sports Sciences158 citationsOpen Access

Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR

View Full Paper
YBYang BaiPHPaul R. HibbingKMKonstantinos Mantis

Structured PICO

Do the Apple Watch 1 and Fitbit Charge HR accurately measure energy expenditure, steps, and heart rate compared to criterion measures in healthy adults?

P
Population
39 healthy adults
I
Intervention
Apple Watch 1 and Fitbit Charge HR worn during a semi-structured activity protocol (20 minutes sedentary, 25 minutes aerobic, 25 minutes light intensity)
C
Comparator
Criterion measures: Oxycon Mobile for energy expenditure, pedometer for steps, and Polar chest strap for heart rate
O
Outcome
Validity of energy expenditure, steps, and heart rate (measured by mean absolute percent error)surrogate

The Apple Watch 1 is more accurate for estimating energy expenditure, while the Fitbit Charge HR provides accurate heart rate monitoring comparable to a chest strap.

Abstract

The purpose of this investigation was to examine the validity of energy expenditure (EE), steps, and heart rate measured with the Apple Watch 1 and Fitbit Charge HR. Thirty-nine healthy adults wore the two monitors while completing a semi-structured activity protocol consisting of 20 minutes of sedentary activity, 25 minutes of aerobic exercise, and 25 minutes of light intensity physical activity. Criterion measures were obtained from an Oxycon Mobile for EE, a pedometer for steps, and a Polar heart rate strap worn on the chest for heart rate. For estimating whole-trial EE, the mean absolute percent error (MAPE) from Fitbit Charge HR (32.9%) was more than twice that of Apple Watch 1 (15.2%). This trend was consistent for the individual conditions. Both monitors accurately assessed steps during aerobic activity (MAPEApple: 6.2%; MAPEFitbit: 9.4%) but overestimated steps in light physical activity. For heart rate, Fitbit Charge HR produced its smallest MAPE in sedentary behaviors (7.2%), followed by aerobic exercise (8.4%), and light activity (10.1%). The Apple Watch 1 had stronger validity than the Fitbit Charge HR for assessing overall EE and steps during aerobic exercise. The Fitbit Charge HR provided heart rate estimates that were statistically equivalent to Polar monitor.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bai et al. (2017) studied this question.

synapsesocial.com/papers/69deab8a1d9bba5129b0c8a9https://doi.org/10.1080/02640414.2017.1412235
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparison of Step Outputs for Waist and Wrist Accelerometer Attachment Sites2014 · 216 citations
  2. 2The Usefulness of Activity Trackers in Elderly with Reduced Mobility: A Case Study2013 · 55 citations
  3. 3The Advantages of Wearable Green Reflected Photoplethysmography2010 · 205 citations
  4. 4Heart Rate monitoring during physical exercise using wrist-type photoplethysmographic (PPG) signals2015 · 30 citations
  5. 5Studies in health technology and informatics2008 · 2,903 citations