Why the study?
Does right atrial pacing to increase maximal heart rate improve cardiovascular capacity and VO2 max during maximal exercise in healthy humans?
Does right atrial pacing to increase maximal heart rate improve cardiovascular capacity and VO2 max during maximal exercise in healthy humans?
Increasing maximal heart rate via right atrial pacing does not increase maximal cardiac output or VO2 max in healthy humans, indicating that maximal heart rate does not limit cardiovascular capacity.
Atrial pacing to raise HRmax should not be pursued to boost exercise capacity; leaves open whether heart rate limits VO2max in other populations.
In humans, maximal aerobic power (VO2 max ) is associated with a plateau in cardiac output (Q), but the mechanisms regulating the interplay between maximal heart rate (HRmax) and stroke volume (SV) are unclear. To evaluate the effect of tachycardia and elevations in HRmax on cardiovascular function and capacity during maximal exercise in healthy humans, 12 young male cyclists performed incremental cycling and one-legged knee-extensor exercise (KEE) to exhaustion with and without right atrial pacing to increase HR. During control cycling, Q and leg blood flow increased up to 85% of maximal workload (WLmax) and remained unchanged until exhaustion. SV initially increased, plateaued and then decreased before exhaustion (P < 0.05) despite an increase in right atrial pressure (RAP) and a tendency (P = 0.056) for a reduction in left ventricular transmural filling pressure (LVFP). Atrial pacing increased HRmax from 184 ± 2 to 206 ± 3 beats min(-1) (P < 0.05), but Q remained similar to the control condition at all intensities because of a lower SV and LVFP (P < 0.05). No differences in arterial pressure, peripheral haemodynamics, catecholamines or VO2 were observed, but pacing increased the rate pressure product and RAP (P < 0.05). Atrial pacing had a similar effect on haemodynamics during KEE, except that pacing decreased RAP. In conclusion, the human heart can be paced to a higher HR than observed during maximal exercise, suggesting that HRmax and myocardial work capacity do not limit VO2 max in healthy individuals. A limited left ventricular filling and possibly altered contractility reduce SV during atrial pacing, whereas a plateau in LVFP appears to restrict Q close to VO2 max .
No takes yet. Share an insight, caveat, or question.
Munch et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: