Answers are grounded in this paper and cite their sources.
Berry Syndrome is a rare combination of congenital cardiac abnormalities firstly reported in 1982.1 It consists of aortopulmonary window, anomalous origin of the right pulmonary artery (RPA) from ascending aorta, intact ventricular septum, interruption of the aortic arch with patent ductus arteriosus(PDA). This is the 26th case reported in literature2 and the first report in Hong Kong. Delayed recognition can result in potential lethal condition. This report demonstrated the importance of prompt clinical recognition, timely echocardiography and early operation in the management of this rare cardiac anomaly. CASE REPORT A baby girl was born at 41 weeks and 2 days of gestation by vaginal delivery with birth weight of 2.68 kg. The perinatal history was unremarkable and she was the first baby of a family without history of congenital heart disease. Routine neonatal screening at 24 hours of life revealed no dysmorphism, normal heart sounds and a grade 2/6 ejection systolic murmur over the left upper sternal border. The murmur was persistent at 48 hours of life with strong femoral pulses, no difference of blood pressure between the upper and lower limbs, no clinical cyanosis or evidence of heart failure. However, there was differential cyanosis detected by pulse oximetry measurement. The oxygen saturation of the upper limbs and lower limbs were 100% and 86%, respectively. Chest X-ray and electrocardiogram were normal for age. Transthoracic echocardiography was performed which showed the features of Berry syndrome. At parasternal long axis view (Fig. 1A), the RPA was shown to arise from the posterior aspect of the ascending aorta. At high parasternal short axis view with slight anterosuperior angulation (Fig. 1B), a 6 mm type II aortopulmonary window (AP window) was detected with Colour Doppler showing bidirectional flow between the ascending aorta and pulmonary trunk. The RPA could also be seen in this view arising from the posterior aspect of the aorta, directing to the right and posteriorly. At suprasternal long axis view, type A interrupted aortic arch was found (Fig. 2A). A large PDA 5 mm in size connecting the bifurcation of the pulmonary trunk to the descending aorta (Des Ao) was also shown (Fig. 2B). Doppler study revealed bidirectional flow at the ductus arteriosus with predominant right to left shunt and diastolic reversal flow at the descending aorta. From the subcostal view, the anomalous origin of the RPA from the ascending aorta could also be demonstrated. There was also a small patent foramen ovale of 2 mm in diameter with left to right shunt but there was no ventricular septal defect. The contractility of the ventricles was satisfactory. Renal function test was normal and blood gas analysis showed no acidosis indicating the descending aorta was well perfused by the right ventricle through the ductus arteriosus. Chromosomal study revealed no abnormality.Fig. 1. A.: Parasternal long axis view shows anomalous RPA from the posterior aspect of ascending aorta. B. High parasternal short axis view shows a 6 mm type II AP window.Fig. 2. A.: Suprasternal long axis view shows type A interrupted aortic arch. B. Suprasternal long axis view shows a 5 mm PDA connected the bifurcation of the main pulmonary trunk with the descending aorta.Prostaglandin E2 at a dose of 0.005 mg · kg-1 · min-1 was infused to maintain the patency of the ductus. A successful staged operation with repair of aortic arch, ligation of ductus arteriosus, closure of aortopulmonary window and reimplantation of RPA was commenced on day 3 of life in the Paediatric Cardiac Center of Hong Kong at the Grantham Hospital. Operative findings revealed type A interruption of aortic arch with the transverse arch, ductus arteriosus and descending arch measured 3 mm, 5 mm and 4 mm respectively. The RPA and main pulmonary arterial trunk were found connecting to the posterior aspect of mid ascending aorta. The baby was well and enjoyed normal development on follow up at one year of age. Echocardiographic study showed good cardiac function with mild residual coarctation of aorta and RPA stenosis. DISCUSSION The association of distal aortopulmonary window, anomalous origin of the right pulmonary artery, intact ventricular septum, interruption of the aortic arch with patent ductus arteriosus was firstly reported by Berry et al1 as a syndrome in 1982. The incidence of this rare combination of anomalies among patients with congenital heart disease is estimated to be 0.046%,3 and it has not been reported in Hong Kong. Richardson and his colleagues4 had classified aortopulmonary window into three types according to the anatomy of the defect. Celoria and Patton5 graded the interruption of aortic arch into three types. The anomalous origin of the RPA from the ascending aorta in Berry Syndrome may induce a “steal” phenomenon from the distal aortic arch. This will diminish the blood flow to the distal aortic arch during embryogenesis and result in hypoplasia and interruption of the aortic arch.1 Interruption of the aorta with ductal-dependent systemic circulation is often accompanied by ventricular septal defect. However in type A interruption as in this patient, the association with intact interventricular septum and AP window is more common.6,7 Berry syndrome had been reported to be rarely associated with anomalous origin of the left coronary artery from the main pulmonary artery.8 Of all the published cases, no association with chromosomal abnormality including chromosome 22q11 deletion was reported except one patient with trisomy 13.9 Patients with Berry syndrome would present with severe congestive heart failure, cardiovascular collapse, metabolic acidosis, anuria, and cyanosis when the ductus arteriosus started to close. Early clinical recognition with prompt and accurate echocardiography can lead to the diagnosis. However, it is difficult to make a correct cardiac diagnosis on neonates just depending on clinical signs. Rein et al10 studied 170 term neonates with a persistent heart murmur as the sole clinical sign in the first five days of life by echocardiography. Eighty six percent of them had structural heart lesions; 66% were related to left to right shunt lesions including ventricular septal defect and patent ductus arteriosus; 6 % of them had semilunar valves stenosis; 5% had unforeseen complex congenital heart diseases in which five of them (3%) would be in potentially life threatening conditions if diagnosis were not made early. They included hypoplastic left heart syndrome, transposition of the great arteries, interruption and severe coarctation of the aorta. The strength of the femoral pulses and the difference of blood pressure between the upper and lower limbs are also not reliable clinical signs for detection of coarctation of aorta. Crossland et al11 found that there was a wide variation of blood pressure between the upper and lower limbs in normal neonates. A difference of 20 mmHg was more likely due to random variability in measurement than to genuine coarctation. As the ductus is well patent in the initial few days of patients with ductal dependent systemic circulation, the femoral pulses and the blood pressure in the lower limbs are usually normal. Blood pressure measurement of four limbs is neither a sensitive nor a specific screening tool for coarctation. Richmond et al12 found a routine measurement of postductal oxygen saturation by pulse oximetry a useful adjunct to clinical examination for screening cardiac malformations in asymptomatic newborns when they were more than 24 hours of life. In patients with a ductal dependent systemic circulated, the lower limbs would have a lower oxygen saturation as they were perfused by desaturated blood from the right ventricle through the ductus. Postductal oxygen saturation persistently below 95% was considered abnormal and worth further clinical examination or echocardiography.12 Some patients with the low oxygen saturation were undetectable clinically but measurable by pulse oximetry. One percent of the 6166 newborns screened by Richmond et al12 had persistent desaturation of postductal region to less than 95%. The underlying causes were related to cardiac problems, respiratory abnormalities and sepsis respectively. Ten patients with significant congenital heart disease such as coarctation, transposition of great arteries and persistent pulmonary hypertension of newborn were first brought to clinical suspicion solely by low postductal oximetry readings. As shown in our patient, pulse oximetry measurement of pre and postductal limbs could add further clues to the nature of the underlying cardiac abnormality so that urgent echocardiography and consultation with paediatric cardiologist would be arranged. This was the only reported case that was detected well before symptoms developed. As 8.3 % of newborns with congenital heart diseases in Hong Kong belong to the group with ductal dependent systemic circulation,13 about 15 patients per year may be detected early if routine oximetry is used as an adjunct in screening those neonates with a persistent heart murmur. All components of Berry syndrome can be delineated by echocardiography if it is done properly. A timely echocardiographic study should be offered to newborns with clinical suspicion and having low postductal oxygen saturation. Surgical repair can be performed safely without cardiac catheterization as in previous reports.14,15 This is beneficial in young and unstable patients. Echocardiography can replace cardiac catheterizeation in diagnosing various congenital heart diseases especially in children, as the acoustic windows are satisfactory. Nonetheless, cardiac catheterization still plays an essential role in complex cases in assessing the pulmonary artery pressure, delineating coronary artery abnormalities and locating major aortopulmonary collateral vessels in cases with pulmonary atresia. In conclusion, Berry Syndrome is a rare disease and early clinical recognition with prompt and accurate echocardiography can lead to the diagnosis. The relative lack of physical findings, including that of normal femoral pulses, shows that pulse oximetry measurement of pre and postductal limbs can supplement other clinical signs in diagnosing complex cardiac abnormality with ductal dependent systemic circulation such as interrupted aortic arch, severe coarctation and hypoplastic left heart syndrome. Cardiac operation can be performed safely without cardiac catheterization for some patients if the structural details can be well shown by echocardiography. This is especially beneficial for unstable patients. Acknowledgement: We thank the paediatrc cardiac team at the Grantham Hospital, Hong Kong for offering echocardiographic reassessment and early surgery for this patient.
No takes yet. Share an insight, caveat, or question.
Fong et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: