Key result
The lattice-tip catheter increased acute persistent bidirectional CTI block at 60 minutes compared to the standard irrigated focal-tip catheter.
Why the study?
Cavotricuspid isthmus (CTI) ablation is a cornerstone therapy for typical atrial flutter and is commonly performed during atrial fibrillation ablation, motivating a direct randomized comparison between a lattice-tip catheter and a standard irrigated focal-tip catheter for radiofrequency CTI ablation.
Does a lattice-tip catheter improve the acute achievement and persistence of bidirectional cavotricuspid isthmus block after a 60-minute waiting period compared to a standard irrigated focal-tip catheter in patients undergoing radiofrequency CTI ablation?
RCT (n=102)
Open-label
1:1 allocation, randomly permuted blocks, stratified by trial centre
Yes
Does a lattice-tip catheter improve the acute achievement and persistence of bidirectional cavotricuspid isthmus block after a 60-minute waiting period compared to a standard irrigated focal-tip catheter in patients undergoing radiofrequency CTI ablation?
Radiofrequency CTI ablation with a large-footprint lattice-tip catheter achieves superior acute persistent bidirectional block and higher procedural efficiency (shorter ablation time and fewer lesions) compared to standard contact-force irrigated focal-tip ablation when rigorously validated by high-density mapping and adenosine testing.
Answers are grounded in this paper and cite their sources.
Supports lattice-tip use for higher CTI ablation success; confirms randomized superiority over focal-tip catheters for persistent block.
AIMS: Cavotricuspid isthmus (CTI) ablation is a cornerstone therapy for typical atrial flutter (AFl) and is commonly performed during atrial fibrillation (AF) ablation. In this multicentre randomized trial, we compared a lattice-tip catheter with an irrigated focal-tip catheter for radiofrequency CTI ablation (LINEAR study-ClinicalTrials.gov NCT07078760). METHODS AND RESULTS: Patients were randomized to a lattice-tip, dual-energy catheter (lattice-tip group) or to a standard 3.5-mm irrigated radiofrequency catheter (standard group) in two centres. In the lattice-tip group, only radiofrequency was utilized. The primary endpoint was the achievement and persistence of bidirectional CTI block after a 60-minute waiting period, confirmed by high-density electroanatomical mapping and adenosine testing. Secondary endpoints included the rate of first-pass block, the number of lesions, and the ablation time. Procedural complications were recorded. In total, 102 patients were randomized. The primary endpoint was achieved in significantly more patients in the lattice-tip as compared to the standard group (94.1% vs. 68.6%, P = 0.002). The lattice-tip catheter resulted in a significantly higher rate of first-pass block (90.2% vs. 60.8%, P = 0.001). CTI block required significantly shorter ablation time (41.3 ± 12.1 vs. 245.3 ± 91.3 s, P < 0.001) and a significantly lower number of lesions (8.3 ± 2.4 vs. 13.4 ± 4.5, P < 0.001) in the lattice-tip as compared to the standard group. No procedural complications were documented. CONCLUSION: The lattice tip catheter resulted in higher acute procedural success for radiofrequency CTI ablation compared to the standard irrigated focal-tip catheter. Future studies are needed to assess long-term efficacy and clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Tzeis et al. (2026) conducted an RCT in Cavotricuspid isthmus-dependent atrial flutter and/or atrial fibrillation scheduled for CTI ablation (n=102). Lattice-tip dual-energy catheter (Sphere-9) radiofrequency CTI ablation vs. Standard 3.5-mm irrigated focal-tip radiofrequency catheter (ThermoCool SmartTouch SF, 30 W, target contact force 10-30 g, target AI 450) was evaluated on Achievement and persistence of bidirectional CTI block after a 60-minute waiting period, confirmed by differential pacing, high-density electroanatomical mapping, and adenosine testing (p=0.002). The lattice-tip catheter increased acute persistent bidirectional CTI block at 60 minutes compared to the standard irrigated focal-tip catheter.
Synapse has enriched 10 related papers. Consider them for comparative context: