Answers are grounded in this paper and cite their sources.
Innovative thermography method measures temperature accurately in high-temperature environments, indicating strong reliability.
Near-infrared multispectral light-field (NIR-MSLF) thermography was developed for wide-range temperature measurement. By integrating an optical-filter-array with a near-infrared light-field camera, the system enables single-shot acquisition of two-dimensional (2D) temperature distributions of high-temperature objects. Blackbody calibration experiments demonstrated the lower temperature threshold successfully extended to 573 K compared with that of visible multispectral light-field thermography, and errors were maintained below ±10 K over 573–1873 K. Furthermore, to address the effect of intense ambient radiation on accurate temperature calculation, a three-dimensional view-factor mapping (3D-VFM) method was proposed to quantify ambient radiation. By projecting three-dimensional geometric elements onto the pixel plane, the method derives a 2D view-factor distribution, enabling pixel-level correction of ambient radiation. The reliability of the proposed NIR-MSLF thermography and 3D-VFM method was validated through turbine blade film cooling experiments. Under various coolant flow rates, in conditions where ambient radiation may exceed the radiation from turbine blade itself, the NIR-MSLF thermography measured blade surface temperatures with deviations consistently within ±15 K when compared to the buried thermocouples.
No takes yet. Share an insight, caveat, or question.
Yao et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: