As the number of servers in a data center network (DCN) increases, the probability of server failures is significantly increased. Traditional connectivity is an important metric to measure the reliability of DCN. However, the traditional connectivity of a DCN based on the condition of arbitrary faulty servers is generally lower. Therefore, it is important to increase the connectivity of a DCN by adding some limited conditions for the faulty server set. As a result, g-restricted connectivity and h-extra connectivity, which are two crucial subjects for a DCN’s ability to tolerate faulty servers, were proposed in the literature. In this paper, we study the g-restricted connectivity and h-extra connectivity of a new server-centric DCN, called BCDC, based on crossed cube with excellent performance. We prove that the g-restricted connectivity of BCDC is 4 for $n=3$ and $2n+g(n-2)-2$ for n≥ 4, where 0≤ g≤ n-3, and the h-extra connectivity of BCDC is 4 for $n=3$ and $2n+h(n-2)-2$ for n≥ 4, where 0≤ h≤ n-3.
No takes yet. Share an insight, caveat, or question.
Lv et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: