Key result
Automated 3D MAPSE shows adequate agreement with manual measurements, with ~1.4 mm bias post-cardiac surgery.
Why the study?
Does 3D autoMAPSE provide precise and accurate continuous monitoring of left ventricular function compared to manual MAPSE in adult intensive care patients after cardiac surgery?
Observational (n=50)
Does 3D autoMAPSE provide precise and accurate continuous monitoring of left ventricular function compared to manual MAPSE in adult intensive care patients after cardiac surgery?
3D autoMAPSE using deep learning and 3D transesophageal echocardiography provides feasible, precise, and accurate continuous monitoring of left ventricular longitudinal function in post-cardiac surgery patients.
Answers are grounded in this paper and cite their sources.
Supports automated perioperative LV monitoring; leaves open outcome trials before clinical adoption.
Aims Continuous monitoring of left ventricular (LV) function may improve cardiopulmonary management. Therefore, we have developed 3D autoMAPSE, a novel method that combines 3D transesophageal echocardiography and deep learning to automatically measure mitral annular plane systolic excursion (MAPSE). We hypothesized that 3D autoMAPSE could provide continuous monitoring of LV function in perioperative patients. Methods and results This prospective observational study included 50 adult intensive care patients after cardiac surgery. Single-beat full-volume 3D recordings were obtained every 5 min over a 120-min period using a hands-free method that simulated continuous monitoring with transesophageal echocardiography. Precision and agreement with manual MAPSE were determined by a test-retest study design during hemodynamic stability. Our results show that continuous monitoring by 3D autoMAPSE had excellent feasibility (99%). It analysed 10 cycles instantaneously (55 ± 15 s) with high precision (least significant change 1.6 mm). 3D autoMAPSE had adequate agreement with manual MAPSE (bias –1.4 mm, limits of agreement −4.0 to 1.2 mm). Continuous 3D autoMAPSE was associated with both N-terminal pro B-type natriuretic peptide (rho = −0.37, P = 0.008) and high-sensitivity troponin-T (rho = −0.28, P = 0.047). This association was slightly stronger than for LV ejection fraction or any other single echocardiographic measurement. Conclusion 3D autoMAPSE provided continuous monitoring of LV function in perioperative patients by obtaining highly feasible and precise measurements that agree with manual echocardiography and postoperative biomarkers. Thus, continuous 3D autoMAPSE may be an attractive complement to hemodynamic monitoring that can aid cardiopulmonary management.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2025) conducted an observational in post-cardiac surgery (n=50). 3D autoMAPSE vs. manual MAPSE was evaluated on Agreement with manual MAPSE (bias -1.4 mm, 95% CI -4.0 to 1.2). Continuous monitoring of left ventricular function using 3D autoMAPSE showed adequate agreement with manual MAPSE in post-cardiac surgery patients.
Synapse has enriched 10 related papers. Consider them for comparative context: