Key result
LVAD unloading is linked to ~33% higher microvascular density in failing human hearts.
Why the study?
The effect of LVAD mechanical unloading on cardiac endothelium, microvasculature, fibrosis, and hypertrophy regression in the failing human heart is unknown and controversial.
Does LVAD mechanical unloading alter myocardial microvasculature, fibrosis, and hypertrophy in patients with chronic heart failure?
Observational (n=23)
Does LVAD mechanical unloading alter myocardial microvasculature, fibrosis, and hypertrophy in patients with chronic heart failure?
Mechanical unloading with an LVAD in failing human hearts increases microvascular density and fibrosis without inducing cardiomyocyte atrophy.
Should not yet change LVAD practice in chronic HF; leaves open whether microvascular remodeling aids myocardial recovery.
OBJECTIVES: This study investigates alterations in myocardial microvasculature, fibrosis, and hypertrophy before and after mechanical unloading of the failing human heart. BACKGROUND: Recent studies demonstrated the pathophysiologic importance and significant mechanistic links among microvasculature, fibrosis, and hypertrophy during the cardiac remodeling process. The effect of left ventricular assist device (LVAD) unloading on cardiac endothelium and microvasculature is unknown, and its influence on fibrosis and hypertrophy regression to the point of atrophy is controversial. METHODS: Hemodynamic data and left ventricular tissue were collected from patients with chronic heart failure at LVAD implant and explant (n = 15) and from normal donors (n = 8). New advances in digital microscopy provided a unique opportunity for comprehensive whole-field, endocardium-to-epicardium evaluation for microvascular density, fibrosis, cardiomyocyte size, and glycogen content. Ultrastructural assessment was done with electron microscopy. RESULTS: Hemodynamic data revealed significant pressure unloading with LVAD. This was accompanied by a 33% increase in microvascular density (p = 0.001) and a 36% decrease in microvascular lumen area (p = 0.028). We also identified, in agreement with these findings, ultrastructural and immunohistochemical evidence of endothelial cell activation. In addition, LVAD unloading significantly increased interstitial and total collagen content without any associated structural, ultrastructural, or metabolic cardiomyocyte changes suggestive of hypertrophy regression to the point of atrophy and degeneration. CONCLUSIONS: The LVAD unloading resulted in increased microvascular density accompanied by increased fibrosis and no evidence of cardiomyocyte atrophy. These new insights into the effects of LVAD unloading on microvasculature and associated key remodeling features might guide future studies of unloading-induced reverse remodeling of the failing human heart.
No takes yet. Share an insight, caveat, or question.
Drakos et al. (2010) conducted an observational in chronic heart failure (n=23). Left ventricular assist device (LVAD) unloading vs. Pre-LVAD (implant) state and normal donors was evaluated on Microvascular density and microvascular lumen area (p=0.001). Left ventricular assist device unloading in failing human hearts resulted in a 33% increase in microvascular density (P=0.001) and a 36% decrease in microvascular lumen area (P=0.028).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: