Demonstrates effective monitoring and control strategies for bridge construction, indicating safe construction practices.
This study focuses on a double-tower, double-plane prestressed concrete cable-stayed bridge with a span arrangement of 75+130+365+130+75 m. A full-bridge finite element model was developed using Midas Civil, and a monitoring system was established to track main girder alignment, cable forces, and structural stresses. A phased control and monitoring strategy is implemented: alignment control is prioritized during the cantilever casting stage, while cable force and stress control take precedence during the closure stage. Monitoring results indicate that the alignment of the completed bridge's main girder is smooth, with cable force deviations controlled within 10 %, and stresses in both the main girder and pylons remaining within safe limits. This study integrates dynamic control and monitoring strategies, offering practical references for the construction control of similar bridges.