Randomized trial evaluates the thermal performance of alternative materials in hydrogen tanks, suggesting enhanced efficiency and safety.
The significant heat generated during the refueling of hydrogen pressure tanks may exceed the permissible 85 °C temperature limit for type IV tanks. Common countermeasures such as hydrogen pre-cooling or long filling times are energy- and time-consuming; hence, in this paper, passive means through thermally better-suited materials are examined. State-of-the-art and alternative materials are first characterized and finally compared using a transient heat model. Different material combinations are compared in terms of the maximum temperature and weight in a typical filling scenario. As alternative liner materials, thermoplastics filled with short carbon fibers, minerals, and graphite were selected to improve thermal properties. For the composite overwrap, copper-coated carbon fibers were chosen. The findings show that the liner is the bottleneck while transferring heat from the inner to the outer tank surface. Using graphite-filled thermoplastics as the liner material shows the greatest potential regarding thermal optimization with only a slight weight increase. Using copper-coated carbon fibers additionally further reduces the maximum temperature but results in a significant weight increase.
No takes yet. Share an insight, caveat, or question.
Liebers et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: