Key result
New-generation balloon-expandable TAVI carries a ~2% rate of clinically relevant haemolysis.
Why the study?
What is the incidence and clinical course of clinically relevant haemolysis after TAVI with new-generation balloon-expandable valves?
Observational (n=282)
No
What is the incidence and clinical course of clinically relevant haemolysis after TAVI with new-generation balloon-expandable valves?
Clinically relevant haemolysis is a rare (2.1%) but significant complication after TAVI with new-generation balloon-expandable valves, often requiring transfusion or reintervention.
Answers are grounded in this paper and cite their sources.
Rare haemolysis after new-generation BEV TAVI warrants monitoring but should not yet change practice; leaves open predictors and prevention strategies.
BACKGROUND: Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce. METHODS: Among 441 patients who underwent TAVI between April 2023 and June 2024, 282 patients treated with new-generation BEV were analysed. Haemolysis was defined based on the lactate dehydrogenase, haemoglobin, reticulocyte and haptoglobin levels. Clinically relevant haemolysis was defined as a case requiring transfusion and/or reintervention. RESULTS: Clinically relevant haemolysis occurred in 6 of 282 patients (2.1%), with median age of 84 years. Three (50%) received a 20 mm valve, and the oversizing ranged from -6.6% to +2.7%. All patients (100%) exhibited paravalvular leakage at the native commissural sites, with moderate or greater paravalvular leakage in two (33%). Lactate dehydrogenase levels exceeded 1200 IU/L in five (83%), four (67%) required transfusion and three (50%) underwent reintervention: balloon aortic valvuloplasty in one and valve-in-valve procedures in two. Haemolysis regressed in three reintervention cases; however, one patient died 9 days postoperatively due to COVID-19. Among three patients (50%) managed conservatively, one developed prosthetic valve endocarditis, whereas another showed spontaneous regression of haemolysis. Over a median follow-up of 218 days, five patients (83%) survived. CONCLUSION: Clinically relevant haemolysis occurred in 2.1% of patients undergoing TAVI with new-generation BEV, with 67% requiring transfusion and 50% undergoing reintervention. Further research is warranted to identify risk factors and optimise management strategies for haemolysis.
No takes yet. Share an insight, caveat, or question.
Higuchi et al. (2025) conducted an observational in Severe aortic stenosis (n=282). Transcatheter aortic valve implantation with new-generation balloon-expandable valve was evaluated on Clinically relevant haemolysis (requiring transfusion and/or reintervention). Clinically relevant haemolysis requiring transfusion or reintervention occurred in 2.1% of patients undergoing transcatheter aortic valve implantation with a new-generation balloon-expandable valve.