Key result
Navitor shows similar device success to Evolut in aortic valve-in-valve procedures.
Why the study?
The influence of stent design versus valve position on outcomes after valve-in-valve procedures with self-expanding transcatheter heart valves remains unclear.
Does a self-expanding intra-annular transcatheter heart valve compared to a supra-annular valve improve clinical and hemodynamic outcomes in patients undergoing aortic valve-in-valve procedures?
Cohort (n=32)
Does a self-expanding intra-annular transcatheter heart valve compared to a supra-annular valve improve clinical and hemodynamic outcomes in patients undergoing aortic valve-in-valve procedures?
Self-expanding intra-annular transcatheter heart valves offer similar hemodynamic and clinical outcomes to supra-annular valves for aortic valve-in-valve procedures, with potentially shorter procedure times.
Answers are grounded in this paper and cite their sources.
Similar outcomes with intra- vs supra-annular THVs in aortic ViV; observational data leave open need for randomized confirmation.
BACKGROUND: Valve-in-valve (ViV) procedures are an established therapy. Self-expanding (SE) supra-annular transcatheter heart valves (THV) achieve superior hemodynamics compared to balloon-expandable (BE) intra-annular THV, but influence of stent design versus valve position remains unclear. AIMS: This study compares SE intra- and supra-annular THV for aortic ViV procedures to further elucidate this topic. METHODS: From 05/2022 to 11/2023, 10 patients underwent ViV procedures with the SE intra-annular Navitor valve. A control group of 22 patients treated with the SE supra-annular Evolut R/PRO valve during the same period was retrieved from our database. Data were retrospectively analyzed according to updated valve academic research consortium (VARC) 3 definitions. A subgroup analysis matched patients for true internal diameter (ID) and body mass index (BMI). RESULTS: Postprocedural transvalvular gradients were similar between groups. No differences in rates of significant paravalvular leakage (PVL) were seen (p = 0.131). No all-cause mortality occurred in either group. Device success (study group, Navitor: 70 [7] vs. control group, Evolut: 90.1 [20]; p = 0.293), early safety (90 [9] vs. 86.4 [19]; p = 1.000), permanent pacemaker implantation (PPI) (0 [0] vs. 9.1 [2]; p = 1.000), and stroke (0 [0] vs. 4.5 [1]; p = 1.000) were similar between groups. Procedure time was shorter for the study group (65.8 ± 27.9 min vs. 145.7 ± 51.3 min; p < 0.001). After matching for True ID and BMI these results persisted. CONCLUSION: Intra- and supra-annular THV showed similar clinical and hemodynamic outcomes in aortic ViV procedures. These findings highlight the applicability of SE intra-annular THV for aortic ViV procedures.
No takes yet. Share an insight, caveat, or question.
Stötzel et al. (2025) conducted a cohort in Aortic Valve-in-Valve procedures (n=32). Self-expanding intra-annular Navitor valve vs. Self-expanding supra-annular Evolut R/PRO valve was evaluated on Device success (p=0.293). The intra-annular Navitor valve showed similar device success compared to the supra-annular Evolut valve in aortic valve-in-valve procedures.
Synapse has enriched 10 related papers. Consider them for comparative context: