Key result
CoreValve Evolut R is linked to ~52% more mild PVL vs SAPIEN-3 in severe calcification.
Why the study?
Does the self-expanding CoreValve Evolut valve frame reduce paravalvular leak compared to the balloon-expandable SAPIEN-3/3 Ultra THV in patients with heavily calcified severe aortic stenosis undergoing TAVR?
Cohort (n=1,513)
Yes
Does the self-expanding CoreValve Evolut valve frame reduce paravalvular leak compared to the balloon-expandable SAPIEN-3/3 Ultra THV in patients with heavily calcified severe aortic stenosis undergoing TAVR?
In heavily calcified aortic stenosis, Evolut PRO and SAPIEN-3/3 Ultra valves have lower paravalvular leak rates than Evolut R, though the CoreValve platform offers superior hemodynamics.
Answers are grounded in this paper and cite their sources.
May favor SAPIEN-3/3 Ultra over Evolut R to limit mild PVL in calcified AS; leaves open comparative outcomes with newer platforms.
BACKGROUND: Heavy calcifications in severe aortic stenosis (AS) pose a major challenge in patients undergoing transcatheter aortic valve replacement (TAVR). Only a few studies have addressed the performance of different transcatheter heart valves (THV) in this subgroup of patients. OBJECTIVES: We aimed to investigate the outcomes of the self-expanding Medtronic CoreValve Evolut valve frame and the balloon-expandable Edwards SAPIEN-3/3 Ultra THV in this challenging patient population. MATERIALS AND METHODS: This was a multicenter registry including a total of 1513 patients with heavily calcified AS undergoing TAVR. The primary endpoint was the incidence and degree of paravalvular leak (PVL) after TAVR. Secondary endpoints were post-implant hemodynamics as well as clinical endpoints according to the VARC-3 definitions. RESULTS: The CoreValve Evolut R but not the Evolut PRO showed significantly higher rates of PVL compared to the SAPIEN-3/3 Ultra (44.8% vs. 29.5% for mild PVL, p < 0.001), while there was no significant difference in ≥ moderate PVL between both groups (p = 0.399). The CoreValve Evolut R and Evolut PRO showed superior THV hemodynamics compared to the SAPIEN-3/3 Ultra group. These findings were confirmed in a propensity score-matched analysis. There were no significant differences regarding short-term outcomes including permanent pacemaker implantation and all-cause mortality between the three groups. CONCLUSION: In patients with severely calcified AS, both CoreValve Evolut PRO and SAPIEN-3/3 Ultra THV showed lower rates of PVL than the CoreValve Evolut R. The self-expanding CoreValve platform had superior post-implant hemodynamics than the SAPIEN-3/3 Ultra system.
No takes yet. Share an insight, caveat, or question.
Saad et al. (2025) conducted a cohort in Heavily calcified aortic valve stenosis (n=1,513). CoreValve Evolut R and Evolut PRO vs. Edwards SAPIEN-3/3 Ultra was evaluated on Incidence of mild paravalvular leak (PVL) after TAVR (p=<0.001). The CoreValve Evolut R showed higher rates of mild paravalvular leak compared to the SAPIEN-3/3 Ultra in patients with severely calcified aortic stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: