Key result
Impella LP2.5 boosts cardiac index ~0.38 L/min/m² more than IABP in AMI cardiogenic shock.
Why the study?
Cardiogenic shock caused by left ventricular failure in AMI patients has high mortality, and it is uncertain if percutaneous LVAD provides superior hemodynamic support compared with IABP.
Does a percutaneous left ventricular assist device (Impella LP2.5) improve cardiac index compared to an intra-aortic balloon pump in patients with cardiogenic shock caused by acute myocardial infarction?
RCT (n=26)
Does a percutaneous left ventricular assist device (Impella LP2.5) improve cardiac index compared to an intra-aortic balloon pump in patients with cardiogenic shock caused by acute myocardial infarction?
In patients with AMI-complicated cardiogenic shock, the Impella LP2.5 provides superior early hemodynamic support compared to IABP, though 30-day mortality was similar.
OBJECTIVES: The aim of this study was to test whether the left ventricular assist device (LVAD) Impella LP2.5 (Abiomed Europe GmbH, Aachen, Germany) provides superior hemodynamic support compared with the intra-aortic balloon pump (IABP). BACKGROUND: Cardiogenic shock caused by left ventricular failure is associated with high mortality in patients with acute myocardial infarction (AMI). An LVAD may help to bridge patients to recovery from left ventricular failure. METHODS: In a prospective, randomized study, 26 patients with cardiogenic shock were studied. The primary end point was the change of the cardiac index (CI) from baseline to 30 min after implantation. Secondary end points included lactic acidosis, hemolysis, and mortality after 30 days. RESULTS: In 25 patients the allocated device (n = 13 IABP, n = 12 Impella LP2.5) could be safely placed. One patient died before implantation. The CI after 30 min of support was significantly increased in patients with the Impella LP2.5 compared with patients with IABP (Impella: DeltaCI = 0.49 +/- 0.46 l/min/m(2); IABP: DeltaCI = 0.11 +/- 0.31 l/min/m(2); p = 0.02). Overall 30-day mortality was 46% in both groups. CONCLUSIONS: In patients presenting with cardiogenic shock caused by AMI, the use of a percutaneously placed LVAD (Impella LP 2.5) is feasible and safe, and provides superior hemodynamic support compared with standard treatment using an intra-aortic balloon pump. (Efficacy Study of LV Assist Device to Treat Patients With Cardiogenic Shock [ISAR-SHOCK]; NCT00417378).
No takes yet. Share an insight, caveat, or question.
Seyfarth et al. (2008) conducted an RCT in Cardiogenic shock caused by acute myocardial infarction (n=26). Left ventricular assist device (Impella LP2.5) vs. Intra-aortic balloon pump (IABP) was evaluated on Change of the cardiac index (CI) from baseline to 30 min after implantation (p=0.02). In patients with cardiogenic shock caused by AMI, the Impella LP2.5 provided superior hemodynamic support compared with IABP (change in cardiac index 0.49 vs 0.11 l/min/m2; p=0.02).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: