Figure 4. SCN5A-E428K iPSC-aCMs displayed abnormal AP profiles and enhanced INa,L (A) Representative AP recordings from healthy control, E428K (middle), and E428-GC (bottom) iPSC-aCMs. (B–E) (B) Atrial APs illustrating the measured parameters in iPSC-aCMs. (C–E) AP parameter comparison among control, E428K, and E428K-GC iPSC-aCMs, including (C) time between two adjacent peaks (interval); (D) maximal rate of rise (dV/dtmax); and (E) AP duration at 90% repolarization (APD90), n = 20 single cells each group; for each group cell, the data were collected from six to eight independent cultures, ∗p < 0.05. (F) Representative whole-cell sodium current traces recorded from control (left), E428K (middle), and E428K-GC iPSC-aCMs. Sodium currents were measured from a holding potential of −120 mV to test potentials ranging between −110 and +20 mV in 5-mV steps, followed by repolarization to −120 mV; dashed line represents 0pA. (G) Current-voltage (I-V) relationship in the three groups of cells. Sodium current amplitude was normalized to the cell capacitance to obtain current density. (H) Voltage dependence of sodium currents activation in the three groups of cells (n = 6 independent experiments each…