Laboratory and field evaluation reveals PCM mortars improve thermal performance in heritage buildings, reducing conductivity and fluctuations.
The energy retrofitting of heritage buildings is constrained by strict requirements on material compatibility, reversibility, and minimal intervention, limiting the use of conventional insulation systems. In this context, lime-based rendering mortars incorporating phase change materials (PCMs) offer a promising solution for enhancing thermal performance while respecting conservation principles. This study investigates the suitability of PCM-enhanced ternary lime-pozzolan-cement mortars through a combined laboratory and field-scale experimental approach, with particular emphasis on real-scale validation under outdoor conditions. Mortars incorporating microencapsulated PCMs were characterized in terms of microstructure, hygric and mechanical properties, thermal conductivity, and latent heat storage, alongside durability assessment under freeze-thaw and salt crystallization cycles. Thermal performance was evaluated using hot-box testing and monitored full-scale mock-ups exposed to real climatic conditions. The results show that PCM incorporation significantly reduces thermal conductivity (from ca. 0.63 to 0.30 W·m -1 ·K -1 ) while providing latent heat storage up to 2.7 J·g -1 . Durability performance was maintained or improved compared to reference mortars. Both laboratory and field-scale results demonstrate the ability of PCM-enhanced mortars to attenuate temperature fluctuations, leading to smoother internal temperature profiles and reduced thermal peaks under real environmental conditions. Overall, the findings confirm that PCM-enhanced ternary lime-based mortars can provide passive thermal buffering while maintaining compatibility with heritage substrates, supporting their application in conservation-oriented energy retrofitting strategies. • PCM-enhanced lime-cement mortars developed for heritage thermal retrofitting. • Thermal conductivity reduced by up to ca. 50% compared to reference mortar. • Up to 5.3% reduction in cyclic peak-to-peak temperature amplitude. • Field monitoring confirms a reduction of indoor temperature fluctuations of approximately 38% in the PCM-enhanced mock-up. • Multi-criteria ranking identifies optimal PCM formulations for façade use.
No takes yet. Share an insight, caveat, or question.
Kyriakou et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: