Why the study?
What are the effects of various cardiovascular properties on cardiac output and central venous pressure in the Fontan circulation compared to a normal biventricular circulation?
What are the effects of various cardiovascular properties on cardiac output and central venous pressure in the Fontan circulation compared to a normal biventricular circulation?
Computational modeling demonstrates that pulmonary vascular resistance, ventricular diastolic function, and systemic vascular compliance are major determinants of cardiac output in the Fontan circulation, emphasizing the need for patient-specific assessment.
Answers are grounded in this paper and cite their sources.
May guide computational Fontan modeling; leaves open human validation before clinical use.
The physiological limitations of the Fontan circulation have been extensively addressed in the literature. Many studies emphasized the importance of pulmonary vascular resistance in determining cardiac output (CO) but gave little attention to other cardiovascular properties that may play considerable roles as well. The present study was aimed to systemically investigate the effects of various cardiovascular properties on clinically relevant hemodynamic variables (e.g., CO and central venous pressure). To this aim, a computational modeling method was employed. The constructed models provided a useful tool for quantifying the hemodynamic effects of any cardiovascular property of interest by varying the corresponding model parameters in model-based simulations. Herein, the Fontan circulation was studied compared with a normal biventricular circulation so as to highlight the unique characteristics of the Fontan circulation. Based on a series of numerical experiments, it was found that 1) pulmonary vascular resistance, ventricular diastolic function, and systemic vascular compliance play a major role, while heart rate, ventricular contractility, and systemic vascular resistance play a secondary role in the regulation of CO in the Fontan circulation; 2) CO is nonlinearly related to any single cardiovascular property, with their relationship being simultaneously influenced by other cardiovascular properties; and 3) the stability of central venous pressure is significantly reduced in the Fontan circulation. The findings suggest that the hemodynamic performance of the Fontan circulation is codetermined by various cardiovascular properties and hence a full understanding of patient-specific cardiovascular conditions is necessary to optimize the treatment of Fontan patients.
No takes yet. Share an insight, caveat, or question.
Liang et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: