Highlights a rare but severe complication (gastroesophageal perforation) associated with intraoperative transesophageal echocardiography even after an easy insertion.
Answers are grounded in this paper and cite their sources.
Alerts clinicians to rare gastroesophageal perforation risk during intraoperative TEE; leaves open true incidence and prevention strategies.
THE use of transesophageal echocardiography for intraoperative monitoring of cardiac function is increasing. Complications are rare. Oropharyngeal injury and hypopharyngeal perforation during difficult insertion of the echoprobe in anesthetized patients have been reported. 1,2 One case of perforation of the cervical esophagus in an awake patient after multiple attempts at insertion of the echoprobe has been reported.3 Esophageal perforation from an echoprobe in an anesthetized patient, however, has not been published. We observed and report a case of perforation of the gastroesophageal junction in an anesthetized patient after an easy insertion of the echoprobe that yielded good quality transesophageal echocardiograms.
No takes yet. Share an insight, caveat, or question.
Kharasch et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: