Why the study?
Does the Spencer Logarithmic Scale (SLS) improve the diagnostic accuracy of Transcranial Doppler (TCD) for detecting large right-to-left shunts compared to International Consensus Criteria (ICC) in patients with ischemic stroke or TIA?
Does the Spencer Logarithmic Scale (SLS) improve the diagnostic accuracy of Transcranial Doppler (TCD) for detecting large right-to-left shunts compared to International Consensus Criteria (ICC) in patients with ischemic stroke or TIA?
Using the Spencer Logarithmic Scale grade III or higher significantly reduces false positive Transcranial Doppler diagnoses for predicting large right-to-left shunts compared to International Consensus Criteria.
SLS may reduce false-positive TCD diagnoses of large RLS; leaves open prospective validation before changing practice.
BACKGROUND: International Consensus Criteria (ICC) consider right-to-left shunt (RLS) present when Transcranial Doppler (TCD) detects even one microbubble (microB). Spencer Logarithmic Scale (SLS) offers more grades of RLS with detection of >30 microB corresponding to a large shunt. We compared the yield of ICC and SLS in detection and quantification of a large RLS. SUBJECTS AND METHODS: We prospectively evaluated paradoxical embolism in consecutive patients with ischemic strokes or transient ischemic attack (TIA) using injections of 9 cc saline agitated with 1 cc of air. Results were classified according to ICC [negative (no microB), grade I (1-20 microB), grade II (>20 microB or "shower" appearance of microB), and grade III ("curtain" appearance of microB)] and SLS criteria [negative (no microB), grade I (1-10 microB), grade II (11-30 microB), grade III (31100 microB), grade IV (101300 microB), grade V (>300 microB)]. The RLS size was defined as large (>4 mm) using diameter measurement of the septal defects on transesophageal echocardiography (TEE). RESULTS: TCD comparison to TEE showed 24 true positive, 48 true negative, 4 false positive, and 2 false negative cases (sensitivity 92.3%, specificity 92.3%, positive predictive value (PPV) 85.7%, negative predictive value (NPV) 96%, and accuracy 92.3%) for any RLS presence. Both ICC and SLS were 100% sensitive for detection of large RLS. ICC and SLS criteria yielded a false positive rate of 24.4% and 7.7%, respectively when compared to TEE. CONCLUSIONS: Although both grading scales provide agreement as to any shunt presence, using the Spencer Scale grade III or higher can decrease by one-half the number of false positive TCD diagnoses to predict large RLS on TEE.
No takes yet. Share an insight, caveat, or question.
Lao et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: