Why the study?
Treating systemic CIED infection with large lead vegetations carries relevant morbidity and mortality, prompting a novel percutaneous aspiration approach before transvenous lead extraction to avoid open surgical complications.
Does percutaneous transcatheter aspiration of large lead vegetations prior to transvenous lead extraction safely facilitate lead removal in patients with CIED infections?
Does percutaneous transcatheter aspiration of large lead vegetations prior to transvenous lead extraction safely facilitate lead removal in patients with CIED infections?
Percutaneous aspiration of large CIED lead vegetations prior to extraction is highly effective and safe, potentially avoiding the need for open surgical extraction and preventing septic embolization.
Answers are grounded in this paper and cite their sources.
May facilitate transvenous extraction in CIED infections with large vegetations; extends observational data but needs randomized confirmation.
AIMS: Treatment of patients with systemic cardiac implantable electronic device (CIED) infection with large lead vegetations is challenging and associated with relevant morbidity and mortality. To avoid complications from open surgical extraction, a novel approach with percutaneous aspiration of large vegetations prior to transvenous lead extraction was instituted. The results of this treatment concept were retrospectively analysed in this multicentre study. METHODS AND RESULTS: One hundred and one patients [mean age 68.2 ± 13.1 (30-92) years] were treated in four centres for endovascular CIED infection with large lead vegetations. Mean lead vegetation size was 30.7 ± 13.5 mm. Two hundred and forty-seven leads were targeted for extraction (170 pacemaker leads, 77 implantable cardioverter-defibrillator leads). Mean lead implant duration was 81.7 (1-254) months. The transcatheter aspiration system with a specialized long venous drainage cannula and a funnel-shaped tip was based on a veno-venous extracorporeal circuit with an in-line filter. The aspiration of vegetations showed complete procedural success in 94.0% (n = 95), partial success in 5.0% (n = 5). Three major complications (3.0%) were encountered. Complete procedural success (per lead) of the subsequently performed transvenous lead extraction procedure was 99.2% (n = 245). Thirty-day mortality was 3.0% (n = 3). Five patients (5.0%) died in the further course on Days 51, 54, 68, 134, and 182 post-procedure (septic complications: n = 4; heart failure: n = 1). CONCLUSION: The percutaneous aspiration procedure is highly effective and is associated with a low complication profile. The aspiration of vegetations immediately prior and during the lead extraction procedure may avoid septic embolization into the pulmonary circulation. This may potentially lead to a long-term survival benefit.
No takes yet. Share an insight, caveat, or question.
Starck et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: