Why the study?
Left bundle branch block is the most common conduction abnormality following TAVR and is associated with adverse outcomes, but data on proposed predictors remain limited.
What are the clinical, anatomic, and device-related predictors of new-onset left bundle branch block following transcatheter aortic valve replacement?
What are the clinical, anatomic, and device-related predictors of new-onset left bundle branch block following transcatheter aortic valve replacement?
Answers are grounded in this paper and cite their sources.
Diabetes, specific valve types and sizes, and certain anatomic and ECG parameters are significant predictors of new-onset LBBB following TAVR, which may help in early risk stratification.
Left bundle branch block (LBBB) is the most common conduction abnormality following transcatheter aortic valve replacement (TAVR) and has been associated with adverse clinical outcomes. While multiple predictors of post-TAVR LBBB have been proposed, data remain limited. This systematic review and meta-analysis aims to identify and summarize predictors of new-onset LBBB post-TAVR. A systematic literature search was performed to identify studies that reported predictors of new-onset post-TAVR LBBB. Extracted data included patient factors, electrocardiographic (ECG) and anatomic parameters, and device-related factors. A random-effects model was used to calculate crude risk ratios (RRs), mean differences, and 95% confidence intervals (CI) of the predictors. Of 450 articles screened, 17 studies comprising a total of 6357 patients were included. Among these, 26.4% developed post-TAVR LBBB. Increased risk was associated with diabetes mellitus (RR: 1.22, p < 0.001), use of 29-mm valve (RR: 1.59, p < 0.001), and use of Medtronic CoreValve (MCV) (RR: 2.25, p = 0.008). Significant differences were found between patients with and without LBBB in interventricular septal thickness (IVS; by -0.66 mm), membranous septal length (MSL; by -0.9 mm), left ventricular outflow tract (LVOT) diameter (by -0.48 mm), PR interval (by +13.95 ms), and prosthesis implantation depth (by +2.6 mm). Diabetes Mellitus, use of 29-mm valve or MCV, decreased IVS thickness, shorter MSL, smaller LVOT diameter, increased prosthesis implantation depth, and prolonged PR duration were all associated with an elevated risk of post-TAVR LBBB. Early identification of these predictors may help reduce the risk of conduction abnormalities after TAVR.
No takes yet. Share an insight, caveat, or question.
Alzu’bi et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: