Key result
Subcutaneous implantable cardioverter-defibrillator combined with coronary sinus ventricular pacing provided effective defibrillation and bradycardia support when transvenous RV leads were unsafe.
Why the study?
Cardiac metastases can trigger malignant ventricular arrhythmias and limit transvenous therapy when right ventricular involvement is present.
Case Report (n=1)
S-ICD combined with coronary sinus ventricular pacing is a practical hybrid strategy for patients requiring defibrillation and bradycardia support when transvenous RV lead placement is unsafe due to tumor involvement.
Answers are grounded in this paper and cite their sources.
Requires caution with transvenous ICDs in RV cardiac metastases; leaves open subcutaneous ICD as hypothesis-generating alternative pending further evidence.
BACKGROUND: Cardiac metastases can trigger malignant ventricular arrhythmias and limit transvenous therapy with right ventricular (RV) involvement. CASE SUMMARY: A 67-year-old patient with metastatic clear-cell renal cell carcinoma and RV metastasis developed ventricular fibrillation during ambulance transport after chest pain and a hypertensive crisis. Coronary angiography revealed severe 3-vessel coronary artery disease, followed by high-risk percutaneous coronary intervention. For secondary prevention, a subcutaneous implantable cardioverter-defibrillator (S-ICD) was implanted because RV lead placement was considered unsafe. Subsequent syncope due to sinus arrest led to discontinuation of beta-blocker therapy and was followed by recurrent ventricular tachycardia treated with 6 appropriate S-ICD shocks. Implantation of a dual-chamber pacemaker with a coronary sinus ventricular lead enabled resumption of beta-blocker therapy, with no further events before discharge. DISCUSSION: In RV tumor involvement where transvenous leads may be unsafe, this case highlights a hybrid strategy providing defibrillation and bradycardia support. TAKE-HOME MESSAGE: S-ICD plus coronary sinus ventricular pacing is a practical option when transvenous RV lead placement is not feasible.
No takes yet. Share an insight, caveat, or question.
Tokcan et al. (2026) conducted a case report in Ventricular fibrillation with right ventricular metastasis (n=1). Subcutaneous implantable cardioverter-defibrillator (S-ICD) and dual-chamber pacemaker with a coronary sinus ventricular lead was evaluated. Subcutaneous implantable cardioverter-defibrillator combined with coronary sinus ventricular pacing provided effective defibrillation and bradycardia support when transvenous RV leads were unsafe.