Key result
Biphasic 150-J AED shocks improve defibrillation, ROSC, and neurological outcomes over monophasic shocks in VF arrest.
Why the study?
This study was conducted to compare an automatic external defibrillator delivering 150-J biphasic shocks against traditional high-energy (200- to 360-J) monophasic AEDs in the resuscitation of out-of-hospital cardiac arrest victims.
Does a 150-J biphasic AED waveform improve defibrillation efficacy, return of spontaneous circulation, survival, and neurological status compared with 200- to 360-J monophasic AED waveforms in patients with out-of-hospital ventricular fibrillation cardiac arrest?
RCT (n=115)
Prospectively randomized according to defibrillation waveform on a daily basis
Yes
Does a 150-J biphasic AED waveform improve defibrillation efficacy, return of spontaneous circulation, survival, and neurological status compared with 200- to 360-J monophasic AED waveforms in patients with out-of-hospital ventricular fibrillation cardiac arrest?
In out-of-hospital ventricular fibrillation cardiac arrest, 150-J biphasic AED shocks improved defibrillation efficacy, return of spontaneous circulation, and neurological outcomes at discharge compared with 200- to 360-J monophasic shocks, despite similar overall survival rates.
Answers are grounded in this paper and cite their sources.
Supports biphasic AED adoption in out-of-hospital VF arrest; confirms randomized superiority over monophasic waveforms.
BACKGROUND: In the present study, we compared an automatic external defibrillator (AED) that delivers 150-J biphasic shocks with traditional high-energy (200- to 360-J) monophasic AEDs. METHODS AND RESULTS: AEDs were prospectively randomized according to defibrillation waveform on a daily basis in 4 emergency medical services systems. Defibrillation efficacy, survival to hospital admission and discharge, return of spontaneous circulation, and neurological status at discharge (cerebral performance category) were compared. Of 338 patients with out-of-hospital cardiac arrest, 115 had a cardiac etiology, presented with ventricular fibrillation, and were shocked with an AED. The time from the emergency call to the first shock was 8.9+/-3.0 (mean+/-SD) minutes. CONCLUSIONS: The 150-J biphasic waveform defibrillated at higher rates, resulting in more patients who achieved a return of spontaneous circulation. Although survival rates to hospital admission and discharge did not differ, discharged patients who had been resuscitated with biphasic shocks were more likely to have good cerebral performance.
No takes yet. Share an insight, caveat, or question.
Schneider et al. (2000) conducted an RCT in Out-of-hospital cardiac arrest with ventricular fibrillation of cardiac etiology (n=115). Biphasic waveform automatic external defibrillator (AED) shocks vs. Traditional high-energy (200- to 360-J) monophasic AED shocks was evaluated on Defibrillation efficacy, return of spontaneous circulation, survival to hospital admission and discharge, and neurological status at discharge (cerebral performance category). 150-J biphasic AED shocks achieved higher defibrillation, return of spontaneous circulation, and good cerebral performance rates than 200-360-J monophasic shocks in 115 VF arrest patients.