Why the study?
The study was conducted to assess whether left bundle branch pacing can preserve physiological cardiac synchrony and provide favorable hemodynamic effects.
Does left bundle branch pacing preserve physiological cardiac synchrony compared to right ventricular septum pacing in patients with sick sinus syndrome?
Does left bundle branch pacing preserve physiological cardiac synchrony compared to right ventricular septum pacing in patients with sick sinus syndrome?
Left bundle branch pacing preserves left ventricular mechanical synchrony and hemodynamic function similarly to native conduction and superiorly to right ventricular septum pacing in patients with sick sinus syndrome.
May support LBBP for preserving LV synchrony similar to native conduction in SSS patients; leaves open superiority over RVSP pending randomized trials.
AIM: The aim of this study is to assess if left bundle branch pacing (LBBP) can preserve physiological cardiac synchrony and deliver favorable hemodynamic effects. METHODS: Consecutive patients undergoing dual chamber pacemaker implantation for sick sinus syndrome (SSS) and a normal cardiac function with a narrow QRS complex were recruited for the study. Electrocardiogram and echocardiographic examinations were performed during ventricular pacing-on and native-conduction modes. The QRS duration (QRSd), systolic dyssynchrony index (SDI), and the standard deviation of time-to-peak contraction velocity in left ventricular (LV) 12 segments (Tsd-12-LV) were measured to evaluate LV synchrony. The stroke volume (SV) and the degree of atrioventricular valvular regurgitation were also assessed. RESULTS: A total of 40 patients underwent LBBP, while another 38 patients underwent right ventricular septum pacing (RVSP) as control group. Baseline characteristics were similar between the two groups. With LBBP, the paced QRSd was slightly wider than the intrinsic QRSd (101.03 ± 8.79 ms vs 91.06 ± 14.17 ms, P < .0001) while the LV mechanical synchrony during LBBP pacing mode was similar to that of native-conduction mode (SDI, 3.14 ± 2.49 vs 2.70 ± 1.68, P = 0.129; Tsd-12-LV, 26.43 ± 15.55 vs 25.61 ± 16.07, P = .671) in the LBBP group. The LV synchrony in the LBBP group was superior to the RVSP group significantly. No significant differences in SV (64.08 ± 16.97 mL vs 65.45 ± 18.68 mL, P = .241) or the degree of atrioventricular valvular regurgitation were noted between LBBP capture and native-conduction modes. CONCLUSION: LBBP could preserve satisfactory LV synchrony and result in favorable hemodynamic effects.
No takes yet. Share an insight, caveat, or question.
Cai et al. (2020) studied this question.