Why the study?
Clinical data comparing supra-annular self-expanding valves and intra-annular self-expanding valves after TAVI are scarce, particularly in patients with a small aortic annulus.
Do intra-annular self-expanding valves compared to supra-annular self-expanding valves improve early clinical and echocardiographic outcomes in patients with small aortic annuli undergoing TAVI?
Do intra-annular self-expanding valves compared to supra-annular self-expanding valves improve early clinical and echocardiographic outcomes in patients with small aortic annuli undergoing TAVI?
In patients with small aortic annuli undergoing TAVI, intra-annular and supra-annular self-expanding valves provide similar early clinical outcomes, though intra-annular valves are associated with slightly higher mean pressure gradients.
Answers are grounded in this paper and cite their sources.
IA-SEVs linked to modestly higher gradients without early clinical differences; leaves open longer-term implications in small-annuli TAVI.
BACKGROUND: Clinical data are scarce comparing supra-annular self-expanding valves (SA-SEVs) and intra-annular (IA)-SEVs after transcatheter aortic valve implantation (TAVI), particularly in patients with a small aortic annulus (SAA). AIMS: We aimed to compare early clinical outcomes, including echocardiographic parameters, between the latest generation of IA-SEV and SA-SEV after TAVI in patients with SAA. Differences in valve design on postprocedural results were investigated between the two groups and in the propensity score-matched (PSM) cohort. RESULTS: The postprocedural effective orifice area (EOA), indexed EOA, and mean pressure gradient (mPG) were similar in the overall cohort between the two groups (allp>0.05), whereas the mPG was higher with IA-SEVs than with SA-SEVs (8.74±5.01 mmHg vs 7.84±4.43 mmHg; p=0.049) after PSM (n=219 patients/group). There were no significant differences in the incidence of severe prosthesis-patient mismatch (1.9% vs 0.9%; p=0.405) or paravalvular leakage ≥mild (34.1% vs 42.2%; p=0.084) between the 2 groups in the PSM cohort. The rates of technical success (95.9% vs 95.8%), device success at discharge (91.3% vs 87.8%), and in-hospital death (1.4% vs 0.5%) were comparable in the overall cohort (allp>0.05). These results were not changed in the PSM cohort (allp>0.05). CONCLUSIONS: The latest-generation IA-SEV and SA-SEV demonstrated similar clinical results except for a few echocardiographic findings after TAVI in patients with SAA.
No takes yet. Share an insight, caveat, or question.
Yamamoto et al. (2025) studied this question.