Review details criteria to distinguish pathological from benign 18F-FDG PET-CT uptake in prosthetic heart valves.
Why the study?
Interpretation of 18F-FDG PET-CT uptake around prosthetic heart valves is challenging due to physiological factors and confounders causing false-positive or false-negative results.
Provides practical guidance for interpreting 18F-FDG PET-CT imaging in patients with prosthetic heart valves to accurately diagnose endocarditis.
Answers are grounded in this paper and cite their sources.
May aid 18F-FDG PET-CT interpretation in prosthetic valves; leaves open prospective validation of diagnostic criteria.
Imaging is a cornerstone of the diagnosis of prosthetic valve endocarditis. An abnormal 18 F-FDG PET-CT was added as a major diagnostic criterion in the 2015 European Society of Cardiology guidelines for the management of endocarditis. However, interpretation of uptake around prosthetic heart valves (PHVs) can be difficult, because physiological factors and confounders may result in false-positive or false-negative results. This review provides a comprehensive overview of ‘normal’ uptake by reviewing the literature on uptake surrounding non-infected PHVs. We will elaborate on qualitative and quantitative measures of uptake. Then, differences in uptake between different valve types, implant positions and the natural course of uptake over time following PHV implantation will be discussed. Finally, factors possibly hampering assessment or mimicking infection are reviewed. We aim to support clinical implementation of 18 F-FDG PET-CT in suspected prosthetic valve endocarditis and to provide practical guidance to the differentiation between physiological, postoperative and pathological uptake around PHVs.
No takes yet. Share an insight, caveat, or question.
Dalebout et al. (2025) conducted a review in Prosthetic valve endocarditis. 18F-FDG PET-CT was evaluated. A comprehensive review of the literature provides guidance on differentiating physiological, postoperative, and pathological 18F-FDG PET-CT uptake around prosthetic heart valves.
Synapse has enriched 10 related papers. Consider them for comparative context: